Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(32)
ATLANTIC
(25)
AUX
(4)
BOSCH
(75)
BRYANT
(2)
Buderus
(26)
CARRIER
(72)
CIAT
(12)
COLIBRI
(3)
CONFORT AIR
(3)
Candy
(2)
DAIKIN
(415)
EQUATION
(3)
FUJI ELECTRIC
(63)
FUJITSU
(132)
Fujitsu Atlantic
(71)
GENERAL
(117)
GREE
(69)
GSS
(1)
HAIER
(194)
HEC
(0)
HEIWA
(4)
HISENSE
(160)
HITACHI
(75)
IVT
(10)
Inventor
(60)
KAYSUN
(10)
LG
(130)
MIDEA
(409)
MITSUBISHI ELECTRIC
(191)
Mitsubishi Heavy Industries
(146)
NORD
(28)
Nobu
(2)
PANASONIC
(142)
RIELLO
(13)
Rotenso
(0)
SAMSUNG
(118)
THERMOR
(32)
TOSHIBA
(130)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(20)
YORK
(5)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHH14KMCG/ASHH14KMCG-B
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOEH14KMCG/ASEH14KMCG-B
ASE**K
|
FUJITSU | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROH14KMCG/RSH14KMCG-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCH-B
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCH
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOYH14KMCG/ASYH14KMCG
ASY**K
|
Fujitsu Atlantic | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOYH14KMCG/ASYH14KMCG-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
MOX101-07HFN8-QRD1GW/MSCB1BU-07HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.10 | 3.78 | -10° | 2.10 | 1.80 | |
|
MOM-07NXD0/MCB1-07N8-1
Breezeless E
|
MIDEA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.10 | 3.78 | -10° | 2.10 | 1.80 | |
|
MOM-07NXD0/CB1-07HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.10 | 3.78 | -10° | 2.10 | 1.80 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.08 | 3.86 | 22.00 | 12.10 | |||
|
AR70F18C1AWN/AR70F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1AWN/AR60F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18CAAWN/AR60F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1KWN/AR60F18C1KWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18C1AWN/AR70H18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18CACWN/AR70H18CACWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
MX4-22RD1-EF/EF-22RD1
Solunar
|
MIDEA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.71 | -10° | 6.10 | 4.80 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
MUZ-SF35VE/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.88 | -15° | 3.50 | 2.90 | |
|
MUZ-AY15VG/MSZ-AY15VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
MUZ-AY15VG2/MSZ-AY15VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
Z5UW36GFA3 / ZMNW12GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.11 | 4.01 | 3.10 | -10° | 9.00 | 5.90 | |
|
AR50F07C1AHN/AR50F07C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.68 | -11° | 2.00 | 2.10 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
AOYG12KETA /ASYG12KETE
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA /ASYG12KETE-B
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA /ASHG12KETE
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KMCC/RSG12KMCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA /ASHG12KETE-B
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA /RSG12KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA /RSG12KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KMCC/ASYG12KMCE
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETE
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETE-B
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KMCC/ASHG12KMCE
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETE
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETE-B
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KMCC/ASYG12KMCF
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETF
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETF-B
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KMCC/ASHG12KMCF
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETF
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETF-B
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KMCC/RSG12KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 |