Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(32)
ATLANTIC
(25)
AUX
(4)
BOSCH
(75)
BRYANT
(2)
Buderus
(26)
CARRIER
(72)
CIAT
(12)
COLIBRI
(3)
CONFORT AIR
(3)
Candy
(2)
DAIKIN
(415)
EQUATION
(3)
FUJI ELECTRIC
(63)
FUJITSU
(132)
Fujitsu Atlantic
(71)
GENERAL
(117)
GREE
(69)
GSS
(1)
HAIER
(194)
HEC
(0)
HEIWA
(4)
HISENSE
(160)
HITACHI
(75)
IVT
(10)
Inventor
(60)
KAYSUN
(10)
LG
(130)
MIDEA
(409)
MITSUBISHI ELECTRIC
(191)
Mitsubishi Heavy Industries
(146)
NORD
(28)
Nobu
(2)
PANASONIC
(142)
RIELLO
(13)
Rotenso
(0)
SAMSUNG
(118)
THERMOR
(32)
TOSHIBA
(130)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(20)
YORK
(5)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RXA50B / FTXA50BT
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BB
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEG24KMTA/ASEG24KMTE
ASE**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
GWH09AVCXB-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
AS50KBAHRA-MW/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
AS50KBAHRA-MB/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
AS50KBAHRA-W/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
U-60PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.27 | -15° | 6.10 | 4.60 | |
|
RZASG71MV1 / FCAG35B / FCAG35B
RZASG
|
DAIKIN | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.05 | 4.31 | 4.31 | -10° | 6.80 | 4.50 | |
|
GWH24AUDXF-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
GWH24AUDXF-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
HMIP2-70W-EUV1 / HMEP2-70-EUV1
HYOKO2
|
HEIWA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
MUZ-EF35VGH/MSZ-EF35VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.50 | 4.21 | -20° | 3.50 | 2.90 | |
|
MUZ-EF35VGH2/MSZ-EF35VGK2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.50 | 4.21 | -20° | 3.50 | 2.90 | |
|
MOX230-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
GFCAGBU-12HRFN8-PRO/GFCAGBU-12HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
X2AGN-12N8D6-OH/AGN-12N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOX201-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOD-12N8D6/MAG1-12N8
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
ΝECUVO-12/ΝECUVI-12WFI
Neo Eco
|
Inventor | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIM-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
MOX230-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
MOX2-12HFN8CD/MSAG-12HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
MCX2-12HFN8CD/MCAG-12HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
AITO-12322.MH/AIT-12322.MH
AIT
|
AIRCLASS | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
NPVO-12/NPVI-12WFI
Neo Plus
|
Inventor | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12326.MH / WIM-12326.MH
WIM 326
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
3AMXM52N9 / ATXM35R / ATXM20R
3AMXM
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.29 | 4.24 | -15° | 5.20 | 4.80 | |
|
3AMXM52N9 / ATXM35A / ATXM20A
3AMXM
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.29 | 4.24 | -15° | 5.20 | 4.80 | |
|
42QHE09D8SH*/38QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.51 | -10° | 2.64 | 2.40 | |
|
MOX201-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
X2AGN-09N8D6-OH/AGN-09N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AOYG12KMCEN/ASYG12KMCEN
ASY**K
|
FUJITSU | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOYG12KMCEN/ASEG12KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
FDC125VNX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 2.70 | 12.50 | 11.40 | ||
|
RZAG125NV1 / FCAG125B
RZAG
|
DAIKIN | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.15 | 4.34 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FCAG125B
RZAG
|
DAIKIN | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.15 | 4.34 | 12.10 | 9.52 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.59 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.59 | 12.10 | 6.00 |