Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(18)
ATLANTIC
(22)
AUX
(4)
BOSCH
(57)
BRYANT
(0)
Buderus
(20)
CARRIER
(31)
CIAT
(4)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(255)
EQUATION
(2)
FUJI ELECTRIC
(21)
FUJITSU
(58)
Fujitsu Atlantic
(28)
GENERAL
(54)
GREE
(32)
GSS
(0)
HAIER
(141)
HEC
(0)
HEIWA
(4)
HISENSE
(82)
HITACHI
(30)
IVT
(9)
Inventor
(40)
KAYSUN
(6)
LG
(30)
MIDEA
(197)
MITSUBISHI ELECTRIC
(76)
Mitsubishi Heavy Industries
(69)
NORD
(16)
Nobu
(0)
PANASONIC
(76)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(47)
THERMOR
(16)
TOSHIBA
(50)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(19)
YORK
(2)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
HDMC-070N-09M25-BK/YDAC-070R-09M25**
Harmonia
|
AIRWELL | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
EMPVO-18/EMPVI-18WFI
Emperor
|
Inventor | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
EMPVO(W)-18/EMPVI(W)-18WFI
Emperor
|
Inventor | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50PDPHRA-TR/1U50KEPFRA-TR
Wall mounted - Pearl Premium
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50QUA1-H/1U50QUA1
NORD - P Premium
|
NORD | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.30 | 4.60 | |
|
AM2-H18/4DR3HA+AMWM-H09/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.30 | -10° | 5.20 | 4.70 | |
|
AM2-H18/4DR3HA+AMWM-H09/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.30 | -10° | 5.20 | 4.70 | |
|
MXZ-2F53VF4/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.10 | -15° | 5.30 | 3.50 | |
|
MXZ-2F53VF5/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.10 | -15° | 5.30 | 3.50 | |
|
AR12TXCACWKN/AR12TXCACWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AR12BXFYDWKN/AR12BXFYDWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
MOD30-24AFN8-QRD1GW/MSEPDU-24HRFN8-QRD1GW
All easy-R32
|
MIDEA | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
MOD30-24HFN8-QRD1GW/MSEPDU-24HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
MOD30-24AFN8-QRD1GW/MSEPDU-24HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
Aero 607-1 O / Aero 607-1 I
Aero 600-1
|
IVT | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
AS25KBAHRA-MB/1U25MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-MW/1U25MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-W/1U25MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
RAM-G68N3HCE / RAK-XJ18QHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.00 | -10° | 6.80 | 5.90 | |
|
AS35KBAHRA-MB/1U35MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
AS35KBAHRA-MW/1U35MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
AS35KBAHRA-W/1U35MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
GWH18AUDXF-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -10° | 5.30 | 4.20 | |
|
RAM-G70N4HCE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 | |
|
RAC-VJ18WHAE / RAK-VJ18RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.82 | -15° | 2.00 | 2.30 | |
|
MXZ-2F42VF4/MSZ-LN18VG2/MSZ-LN25VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 5.10 | -15° | 4.20 | 3.50 | |
|
MXZ-2F42VF5/MSZ-LN18VG3/MSZ-LN25VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 5.10 | -15° | 4.20 | 3.50 | |
|
MUZ-BT20VG/MSZ-BT20VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.30 | 4.55 | -15° | 2.00 | 1.50 | |
|
CU-Z25YKEA / CS-Z25YKEA
2022
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
CU-Z25YKEA-1 / CS-Z25YKEA-1
2024
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
AR70F12C1AWN/AR70F12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AR70F12C1ABN/AR70F12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AR70H12C1ABN/AR70H12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AR70H12C1AWN/AR70H12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
3MXM52A9 / FTXM25R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25R / FTXM25R
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25A / FTXM25A
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP25N9 / FTXP25N9
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
GFCAGBU-09HRFN8-PRO/GFCAGBU-09HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-07N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOD-09N8D6/MAG1-09N8
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
ΝECUVO-09/ΝECUVI-09WFI
Neo Eco
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MOX2-09HFN8CD/MSAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
MCX2-09HFN8CD/MCAG-09HFN8CD
Extreme save R32
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
NPVO-09/NPVI-09WFI
Neo Plus
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 |