Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(4)
AUX
(8)
BOSCH
(11)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(156)
EQUATION
(0)
FUJI ELECTRIC
(33)
FUJITSU
(68)
Fujitsu Atlantic
(35)
GENERAL
(35)
GREE
(6)
GSS
(0)
HAIER
(63)
HEC
(0)
HEIWA
(0)
HISENSE
(23)
HITACHI
(31)
IVT
(0)
Inventor
(16)
KAYSUN
(17)
LG
(52)
MIDEA
(96)
MITSUBISHI ELECTRIC
(133)
Mitsubishi Heavy Industries
(84)
NORD
(6)
Nobu
(0)
PANASONIC
(32)
RIELLO
(11)
Rotenso
(3)
SAMSUNG
(38)
THERMOR
(4)
TOSHIBA
(47)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNP-W/FDT125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.27 | 3.78 | 12.10 | 8.00 | ||
|
RZA200D
RZA
|
DAIKIN | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.10 | 19.00 | 11.20 | |||
|
SUZ-M50VA/SLZ-M50FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.20 | -10° | 4.60 | 3.60 | |
|
SUZ-M50VA2/SLZ-M50FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.20 | -10° | 4.60 | 3.60 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 | |
|
AOYG45LATT/AUYG45LRLA
AOYG**L
|
FUJITSU | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOHG45LATT/AUHG45LRLA
AOHG**L
|
GENERAL | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOYG45LATT/AUYG45LRLA
AOYG**L
|
Fujitsu Atlantic | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AZAS140MV / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AZAS140MY / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
RXM35R9 / FFA35A9
RXM
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.38 | 4.10 | 3.50 | -15° | 3.40 | 3.10 | |
|
FDC125VSX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.04 | 4.08 | 12.50 | 14.00 | ||
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
CU-Z60UBEA / CS-Z60UB4EAW
2017
|
PANASONIC | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 2.92 | -15° | 6.00 | 4.00 | |
|
RAV-GV561ATP-E/RAV-HM561UTP-E
DIC
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.79 | -15° | 5.00 | 2.80 | |
|
RAV-GM1101ATP-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
UUD1 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD3 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD1 U30TK / ZTNW48GALA1
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
AB25S2SC2FA/1U25S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.47 | 3.71 | -10° | 2.50 | 2.80 | |
|
PUZ-SM140VKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
MOD30U-30HFN8-QRD0W(GA)/MCD1-30HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MOD30U-30HFN8-Q(GA)/MCD1-30HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MO-30N8-Q/MCD-30NX
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
KUE-90 DVR13/KCIS-90 DR14
ZEN Cassette
|
KAYSUN | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YUKF30BYEEBMO-1/YKKF30BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
FDC71VNP-W/FDT71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.65 | 4.38 | 4.10 | -15° | 7.10 | 5.70 | |
|
AB71S2SG1FA(H)/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.08 | 4.47 | 3.30 | -10° | 7.10 | 5.00 | |
|
AB71S2SR1FA(H)/1U71S2ST1FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.08 | 4.47 | 3.30 | -10° | 7.10 | 5.00 | |
|
RZAG60B / FCAG60B
RZAG
|
DAIKIN | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.25 | 3.40 | -10° | 6.00 | 4.60 | |
|
SRC60ZSX-W3/FDTC60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.45 | 4.10 | 3.13 | -20° | 5.60 | 5.10 | |
|
AB50S2SC1FA/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.47 | 3.42 | -10° | 5.00 | 4.00 | |
|
MOD30U-30HFN8-QRD1W(GA)/MCD1-30HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
MOD30U-30HFN8-Q1(GA)/MCD1-30HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
MO-30N8-Q-1/MCD-30NX
Cassette R32
|
MIDEA | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 |