Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(9)
ATLANTIC
(0)
AUX
(4)
BOSCH
(6)
BRYANT
(0)
Buderus
(1)
CARRIER
(2)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(24)
HEC
(0)
HEIWA
(0)
HISENSE
(13)
HITACHI
(3)
IVT
(2)
Inventor
(3)
KAYSUN
(3)
LG
(3)
MIDEA
(23)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(3)
Nobu
(0)
PANASONIC
(8)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(3)
TOSHIBA
(0)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
Aero 504 O CN / Aero 504 I CN
Aero 500
|
IVT | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
NF35DBAHRA/1N35MEAFRA
NORD - Console
|
NORD | Console | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
CU-Z25CBEA / CS-Z25CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.47 | -15° | 2.50 | 2.70 | |
|
CU-Z35CBEA / CS-Z35CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.60 | 3.98 | -15° | 3.50 | 3.20 | |
|
CU-Z35UFEA-1 / CS-Z35UFEAW-1
2018
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
CU-Z35CFEA-1 / CS-Z35CFEAW-1
2025
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV140UR4RC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
NF25DBAHRA/1N25MEAFRA
NORD - Console
|
NORD | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
AUV125UR4RC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
AUV125UR4RC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
CU-Z25UFEA-1 / CS-Z25UFEAW-1
2018
|
PANASONIC | Console | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.70 | 4.59 | -25° | 2.50 | 3.00 | |
|
CU-Z25CFEA-1 / CS-Z25CFEAW-1
2025
|
PANASONIC | Console | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.70 | 4.59 | -25° | 2.50 | 3.00 | |
|
RAC-XJ25FHAE / RAF-XJ25RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.77 | |
|
RAC-XJ35FHAE / RAF-XJ35RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.20 | 4.61 | 3.90 | -20° | 3.50 | 3.02 | |
|
RAC-XJ50FHAE / RAF-XJ50RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 7.30 | 4.30 | 3.90 | -20° | 5.00 | 4.19 |