Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(64)
ATLANTIC
(34)
AUX
(131)
BOSCH
(120)
BRYANT
(6)
Buderus
(38)
CARRIER
(129)
CIAT
(27)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(574)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(116)
FUJITSU
(282)
Fujitsu Atlantic
(151)
GENERAL
(202)
GREE
(126)
GSS
(4)
HAIER
(448)
HEC
(5)
HEIWA
(8)
HISENSE
(377)
HITACHI
(110)
IVT
(10)
Inventor
(113)
KAYSUN
(46)
LG
(280)
MIDEA
(664)
MITSUBISHI ELECTRIC
(395)
Mitsubishi Heavy Industries
(204)
NORD
(44)
Nobu
(8)
PANASONIC
(259)
PITSOS
(6)
RIELLO
(29)
Rotenso
(3)
SAMSUNG
(152)
THERMOR
(54)
TOSHIBA
(215)
Viessmann
(13)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(24)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW020D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10P2KVSG-E+RAS-B07P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
SCM60ZS-W/SRK25ZSX-W/SRK35ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.86 | -10° | 6.00 | 4.80 | |
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
RXJ35A / FTXJ35AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A / FTXJ35AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A / FTXJ35AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXA35A8 / FTXA35CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AW9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AB9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
RXJ35A9 / FTXJ35AS9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.73 | 5.15 | 4.04 | -10° | 3.40 | 2.50 | |
|
SRC60ZSX-W3/SRK60ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
SRC60ZSX-W3/SRK60ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
SRC60ZSX-W3/SRK60ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
SRC60ZSX-W3/SRK60ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.70 | 4.12 | -10° | 6.10 | 5.20 | |
|
RXD25A / FTXD25A
RXD
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.59 | -20° | 2.50 | 2.40 | |
|
AS71PEBHRA-PA/1U71WS3FRA
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MB2/1U71WS3FRA
HAIER - FLEXIS S 24k
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MW2/1U71WS3FRA
HAIER - FLEXIS S 24k
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71REBHRA-RBS/1U71WS3FRA
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MWV/1U71WEAFRA-SH
Serene
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-S/1U71WS3FRA
Serene
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
PUZ-ZM71VHA2/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA2/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
MUZ-LN50VG2/MSZ-LN50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
MUZ-LN50VG3/MSZ-LN50VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
CLC8001i 35 E / CLC8001i-W 35 E
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 |