Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(24)
ATLANTIC
(4)
AUX
(20)
BOSCH
(21)
BRYANT
(0)
Buderus
(3)
CARRIER
(34)
CIAT
(19)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(342)
EQUATION
(0)
FUJI ELECTRIC
(61)
FUJITSU
(187)
Fujitsu Atlantic
(88)
GENERAL
(81)
GREE
(6)
GSS
(0)
HAIER
(163)
HEC
(0)
HEIWA
(0)
HISENSE
(52)
HITACHI
(55)
IVT
(2)
Inventor
(26)
KAYSUN
(29)
LG
(89)
MIDEA
(119)
MITSUBISHI ELECTRIC
(211)
Mitsubishi Heavy Industries
(164)
NORD
(13)
Nobu
(0)
PANASONIC
(71)
RIELLO
(19)
Rotenso
(3)
SAMSUNG
(34)
THERMOR
(8)
TOSHIBA
(74)
Viessmann
(13)
Vulcano
(0)
WESTPOINT
(0)
YORK
(13)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-M125YKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
SUZ-M50VA/PCA-M50KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/PCA-M50KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
AD140S2SM3FA/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
AD140S2SM3FA/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
ADH140H1ERG/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 14.00 | 11.00 | ||
|
ADH140H1ERG/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 14.00 | 11.00 | ||
|
5MWXM68A9 / FBA71A9
5MWXM
|
DAIKIN | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -15° | 6.60 | 4.60 | |
|
U-125PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.52 | 3.68 | 3.56 | -15° | 12.10 | 9.30 | |
|
AUW105U4RK7/AUV105UR4RC8
Super Inverter R32
|
HISENSE | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -10° | 9.50 | 8.00 | |
|
UUB1 U20 / CM24F NA0
UU
|
LG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
U-125PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.68 | 3.56 | -15° | 12.10 | 9.30 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 4.19 | 3.74 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 4.19 | 3.74 | -15° | 12.10 | 7.60 | |
|
RXM50A8 / FNA50A9
RXM
|
DAIKIN | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.05 | 3.22 | -15° | 5.00 | 4.00 | |
|
FDC140VNA/FDE140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
FDC140VSA/FDE140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.15 | 3.51 | 13.60 | 10.50 | ||
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
ADH125H1ERG/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.97 | 3.43 | 12.40 | 8.00 | ||
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
ADH140H1ERG/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.98 | 3.97 | 3.43 | 13.40 | 8.50 | ||
|
RAV-GM1602AT8W-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.96 | 3.43 | -15° | 14.00 | 8.40 | |
|
AD125S2SM3FA/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.54 | -10° | 12.10 | 8.00 | |
|
AD125S2SM3FA/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.57 | -10° | 12.10 | 8.00 | |
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
42QZL048D8S/38QUS048D8S
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
UUD1 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZBNW60GM3A1
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
AC71S2SG2FA(H)/1U71S2SR3FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/FDHM-070N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
SC270HIDS8/AIC270HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
AD25S2SS1FA/1U25S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
AD71S2SM3FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.83 | 3.80 | 3.80 | -10° | 6.80 | 5.00 | |
|
SUZ-SM60VA/PEAD-SM60JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA/PEAD-SM60JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA2/PEAD-SM60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 | |
|
AC160S2SK1FA/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
AC160S2SK1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.06 | 4.06 | 3.42 | 16.00 | 11.00 | ||
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 |