Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(11)
ATLANTIC
(0)
AUX
(10)
BOSCH
(13)
BRYANT
(0)
Buderus
(0)
CARRIER
(14)
CIAT
(7)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(47)
EQUATION
(0)
FUJI ELECTRIC
(16)
FUJITSU
(51)
Fujitsu Atlantic
(25)
GENERAL
(25)
GREE
(6)
GSS
(0)
HAIER
(28)
HEC
(0)
HEIWA
(0)
HISENSE
(21)
HITACHI
(24)
IVT
(0)
Inventor
(9)
KAYSUN
(16)
LG
(22)
MIDEA
(58)
MITSUBISHI ELECTRIC
(95)
Mitsubishi Heavy Industries
(30)
NORD
(8)
Nobu
(0)
PANASONIC
(19)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(16)
THERMOR
(2)
TOSHIBA
(22)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AD71S2SS1FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.34 | -10° | 7.10 | 5.00 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
SUZ-M25VA/SEZ-M25DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/SEZ-M25DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SEZ-M25DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
ARXM50R / ADEA50A
ARXM
|
DAIKIN | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.65 | 4.00 | 3.74 | -15° | 5.00 | 4.40 | |
|
ARXM60R / ADEA60A
ARXM
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.74 | 4.00 | 3.63 | -15° | 5.70 | 4.60 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
RAV-GM802ATW-E/RAV-HM801SDTY-E
DI
|
TOSHIBA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 4.00 | 3.44 | -15° | 6.70 | 5.10 | |
|
SUZ-M50VA/SEZ-M50DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/SEZ-M50DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/SEZ-M50DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 5.00 | 4.30 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
SUZ-SM35VA2/PEAD-SM35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.70 | |
|
RXM50A9 / FNA50A9
RXM
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.09 | 3.33 | -10° | 5.00 | 4.00 | |
|
AD71S2SM9FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.06 | 4.00 | 3.34 | -10° | 6.80 | 5.00 | |
|
SUZ-SM35VA/PEAD-SM35JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
SUZ-SM35VA/PEAD-SM35JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
ARXM35R9 / ADEA35A
ARXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 4.00 | 3.97 | -15° | 3.40 | 2.90 | |
|
PUZ-ZM71VHA2/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA2/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AD50S2SM3FA(H)/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.50 | |
|
AD50S2SM9FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.50 | |
|
YDAM-050R-09M25/DDHM-050N-09M22
OASIS
|
AIRWELL | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.50 | |
|
AD71S2SS1FA(H)/1U71S2SR2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.73 | -10° | 7.10 | 5.00 | |
|
AD71S2SM3FA(H)/1U71S2SR2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AD71S2SS1FA/1U71S2SR3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.73 | -10° | 7.10 | 5.00 | |
|
AD71S2SM9FA(H)/1U71S2SR2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
5MWXM68A9 / FBA71A9
5MWXM
|
DAIKIN | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -15° | 6.60 | 4.60 | |
|
UUB1 U20 / CM24F NA0
UU
|
LG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
RXM50A8 / FNA50A9
RXM
|
DAIKIN | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.05 | 3.22 | -15° | 5.00 | 4.00 | |
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
AD125S2SM3FA/1U125S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.54 | -10° | 12.10 | 8.00 | |
|
AD125S2SM3FA/1U125S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.57 | -10° | 12.10 | 8.00 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
AD25S2SS1FA/1U25S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
SUZ-SM60VA/PEAD-SM60JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA/PEAD-SM60JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
SUZ-SM60VA2/PEAD-SM60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.71 | -10° | 6.10 | 4.60 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 |