Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(17)
ATLANTIC
(4)
AUX
(8)
BOSCH
(16)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(156)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(33)
FUJITSU
(68)
Fujitsu Atlantic
(35)
GENERAL
(35)
GREE
(12)
GSS
(0)
HAIER
(63)
HEC
(0)
HEIWA
(0)
HISENSE
(23)
HITACHI
(37)
IVT
(0)
Inventor
(16)
KAYSUN
(27)
LG
(52)
MIDEA
(163)
MITSUBISHI ELECTRIC
(133)
Mitsubishi Heavy Industries
(84)
NORD
(6)
Nobu
(0)
PANASONIC
(32)
PITSOS
(0)
RIELLO
(11)
Rotenso
(5)
SAMSUNG
(38)
THERMOR
(4)
TOSHIBA
(47)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG100NV1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MO-55N8-R/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MUE-55HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
RAV-GM301ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.31 | 4.54 | 4.47 | -15° | 2.50 | 2.30 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/AUXG24KRLB
AUH**K
|
GENERAL | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RCG24KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/AUXG24KRLB
AUXG**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
MOX630U-48HFN8-QRD0W(GA)/MUE-48HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-48NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-42NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-Q(H)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
AUW60U4RJ7/ACT60UR4RJC8
Super Inverter R32
|
HISENSE | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.80 | -10° | 6.20 | 5.50 | |
|
PUZ-ZM250YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.12 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
UUB1 U20 / CT24F NB0
UU
|
LG | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.39 | -10° | 6.80 | 4.10 | |
|
RAS-5HVNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.24 | 3.98 | -20° | 11.90 | 11.93 | |
|
RAS-5HRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.25 | 3.98 | -20° | 11.90 | 11.93 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 | |
|
U-60PZ3E5A / S-60PY3E
2022
|
PANASONIC | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.61 | -15° | 6.00 | 4.60 | |
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
RAV-GM562ATP-E/RAV-HM561MUTP-E
DI
|
TOSHIBA | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.40 | 3.61 | -15° | 5.00 | 2.80 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
RZAG71NV1 / FCAG71B
RZAG
|
DAIKIN | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.83 | 4.22 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FCAG71B
RZAG
|
DAIKIN | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.83 | 4.22 | -10° | 6.80 | 4.70 | ||
|
PUZ-SM100VKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-ZM140YDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
SUZ-M50VA/MLZ-KP50VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
RAV-GM1601ATP-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
FDC125VNA/FDT125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.38 | 3.74 | 12.50 | 9.80 | ||
|
AOYG36KBTB/AUXG36KRLB
AUY**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 |