Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(15)
ATLANTIC
(4)
AUX
(16)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(32)
CIAT
(17)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(342)
EQUATION
(0)
FUJI ELECTRIC
(61)
FUJITSU
(187)
Fujitsu Atlantic
(88)
GENERAL
(81)
GREE
(6)
GSS
(0)
HAIER
(152)
HEC
(0)
HEIWA
(0)
HISENSE
(46)
HITACHI
(55)
IVT
(0)
Inventor
(23)
KAYSUN
(26)
LG
(86)
MIDEA
(96)
MITSUBISHI ELECTRIC
(211)
Mitsubishi Heavy Industries
(164)
NORD
(10)
Nobu
(0)
PANASONIC
(63)
RIELLO
(17)
Rotenso
(3)
SAMSUNG
(34)
THERMOR
(5)
TOSHIBA
(74)
Viessmann
(11)
Vulcano
(0)
WESTPOINT
(0)
YORK
(13)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-4HRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
UUB1 U20 / UL18FH N30
UU
|
LG | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 5.00 | 4.10 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
PUZ-ZM60VHA2/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
UUD1 U30 / UM42FH N30
UU
|
LG | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.85 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42FH N30
UU
|
LG | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.85 | -10° | 12.00 | 9.50 | |
|
MOX330U-18HFN8-QRD0W(GA)/MTJ-18HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MOX330U-18HFN8-Q(GA)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MO-18N8-Q/MTJU-18NX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
KUE-52 DVR13/KPD-52 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
DDMD-050N-09M25 /YDAX-050H-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
42QSV018D8S*/38QUS018D8S-1
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
Vitoclima100-SIDHAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
U7RS-18/V7iDI-18WiFiR
Ducted R32
|
Inventor | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MOX330U-18HFN8-Q(H)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CU-Z35CBEA / CS-Z35CD3EAW
2025
|
PANASONIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.82 | -15° | 3.50 | 2.80 | |
|
UUB1 U20 / UV30F N10
UU
|
LG | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.23 | -10° | 7.50 | 4.40 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.15 | 19.00 | 11.20 | |||
|
PUZ-ZM35VKA2/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
FDC100VNA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
RAV-GP1601AT8-E/RAV-HM1601CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.21 | 3.72 | -20° | 14.00 | 12.00 | |
|
AD50S2SS1FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.73 | -10° | 5.00 | 4.30 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
UUB1 U20 / UM18FH NA0
UU
|
LG | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -10° | 5.00 | 4.40 | |
|
AOYG36KBTB/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KBTB/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KRTA/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 |