Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(29)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(30)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(2)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.34 | 3.61 | 3.13 | -10° | 23.50 | 12.30 | |
|
RZASG100MV1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | 3.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FHA50A9 / FHA50A9
RZASG
|
DAIKIN | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.92 | -10° | 9.50 | 6.00 | ||
|
FDC100VSX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
FDC100VNX/FDE50VH/FDE50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.94 | 3.30 | -20° | 10.00 | 10.80 | |
|
FDC280VSA-W/FDE140VH/FDE140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.95 | 3.34 | 27.00 | 16.00 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.32 | 3.86 | 3.24 | -10° | 20.00 | 11.40 | |
|
FDC100VNA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC140VNX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
FDC140VSX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
FDC100VNA-W/FDE50VH/FDE50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDE50VH/FDE50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.23 | 12.10 | 6.00 | |||
|
FDC100VNX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
FDC100VSX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.39 | 4.10 | 22.00 | 12.10 | |||
|
FDC125VSX/FDE60VH/FDE60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.65 | 4.07 | 3.78 | 12.50 | 14.00 | ||
|
FDC125VNX/FDE60VH/FDE60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.45 | 4.13 | 3.78 | 12.50 | 11.40 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.01 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
FDC250VSA-W/FDE125VH/FDE125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.25 | 3.53 | 25.00 | 14.20 | ||
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
FDC71VNX-W/FDE40VH/FDE40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.48 | 4.49 | 3.81 | -20° | 7.10 | 6.00 | |
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RZAG100NV1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.68 | 4.74 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.68 | 4.74 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.68 | 4.74 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.68 | 4.74 | 13.40 | 7.80 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.64 | 4.64 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.64 | 4.64 | 13.40 | 9.52 | ||
|
RZAG71NV1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FHA35A9 / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.42 | 4.42 | -10° | 6.80 | 4.70 | |
|
FDC125VNA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC140VNX-W/FDE71VH/FDE71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.19 | 4.85 | 4.03 | 14.00 | 13.00 |