Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(26)
ATLANTIC
(4)
AUX
(12)
BOSCH
(22)
BRYANT
(0)
Buderus
(1)
CARRIER
(21)
CIAT
(13)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(156)
EQUATION
(0)
FUJI ELECTRIC
(33)
FUJITSU
(68)
Fujitsu Atlantic
(35)
GENERAL
(35)
GREE
(12)
GSS
(0)
HAIER
(87)
HEC
(0)
HEIWA
(0)
HISENSE
(36)
HITACHI
(37)
IVT
(2)
Inventor
(19)
KAYSUN
(30)
LG
(55)
MIDEA
(186)
MITSUBISHI ELECTRIC
(133)
Mitsubishi Heavy Industries
(84)
NORD
(9)
Nobu
(0)
PANASONIC
(40)
RIELLO
(13)
Rotenso
(5)
SAMSUNG
(38)
THERMOR
(7)
TOSHIBA
(47)
Viessmann
(9)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 3.94 | 3.94 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 3.94 | 3.94 | 13.40 | 9.52 | ||
|
AOYG18KATA/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
ROG18KATA/RCG18KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOHG18KATA/AUXG18KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/AUXG18KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
YUKF48BYOEBMO-1/YFKF48BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -15° | 14.00 | 11.20 | |
|
AUW52U4RS7/ACT52UR4RCC8
Super Inverter R32
|
HISENSE | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -10° | 5.00 | 4.00 | |
|
UUA1 UL0 / UT12FH NQ0
UU
|
LG | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.00 | -10° | 3.40 | 2.80 | |
|
AB25S2SA1FA/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AB25S2SA1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
SRC25ZS-W2/FDTC25VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.08 | -10° | 2.50 | 2.40 | |
|
FDC125VNX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.09 | 4.08 | 12.50 | 11.40 | ||
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
FDMX-050N-09M25/YDAX-050H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MO-18N8-Q/MUEU-18NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
KUE-52 DVR13/KPC-52 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)-GR/MUEU-18HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU2-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUE-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
RZAG50A / FFA50A9
RZAG
|
DAIKIN | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.01 | 3.10 | -20° | 5.00 | 4.30 | |
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
RAV-GV1101AT8P-E/RAV-HM1101UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.33 | -15° | 9.50 | 7.60 | |
|
AZAS140MY1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
AZAS140MV1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
MOX630U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MO-55N8-R-1/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-RRD0W/MUE-55HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-R(GA)/MUE2-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
KUE-160 DTR14/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MO-55N8-R-1/MUE-55NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
J160Xi R14/UO160Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-R(H)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-55HFN8-R OUT V1/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
MOX630U-48HFN8-RRD0W(GA)/MUE-48HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MO-48N8-R-1/MUE-48NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-RRD0W/MUE-48HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MUE2-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
KUE-140 DTR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
MO-48N8-R-1/MUE-42NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 |