Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(38)
ATLANTIC
(4)
AUX
(22)
BOSCH
(37)
BRYANT
(0)
Buderus
(3)
CARRIER
(43)
CIAT
(24)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(386)
DE DIETRICH
(2)
EQUATION
(0)
FUJI ELECTRIC
(77)
FUJITSU
(201)
Fujitsu Atlantic
(104)
GENERAL
(104)
GREE
(18)
GSS
(0)
HAIER
(178)
HEC
(0)
HEIWA
(0)
HISENSE
(70)
HITACHI
(78)
IVT
(2)
Inventor
(34)
KAYSUN
(56)
LG
(119)
MIDEA
(282)
MITSUBISHI ELECTRIC
(301)
Mitsubishi Heavy Industries
(184)
NORD
(19)
Nobu
(0)
PANASONIC
(82)
PITSOS
(0)
RIELLO
(24)
Rotenso
(8)
SAMSUNG
(61)
THERMOR
(12)
TOSHIBA
(92)
Viessmann
(16)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(20)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAC-VJ60NHAE / RAI-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.21 | 3.75 | -10° | 6.00 | 4.70 | |
|
AW-YXDL012-H91/AW-XDL012-N91
XDL
|
AIRWELL | Console | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
YDAF-035R-09M25/XDLF-035N-09M25
XDLF
|
AIRWELL | Console | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
CU-Z60UBEA / CS-Z60UD3EAW
2017
|
PANASONIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
ADH125H1ERG/1U125S2SN3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.43 | 12.40 | 8.00 | ||
|
MOD30U-36HFN8-QRD0W(GA)/MCD1-36HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-Q(GA)/MCD1-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MO-36N8-Q/MCD-36NX
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-QRD0W(GA)/MCD1-36HRFN8-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
KUE-105 DVR13/KCIS-105 DR14
ZEN Cassette
|
KAYSUN | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
U7RS-36/V7CI-36WiFiR
Cassette R32
|
Inventor | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
CDMX-100N-09M25/YDAX-100H-09M25
CDMX
|
AIRWELL | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
YUKF36BYEEBMO-1/YKKF36BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-Q(GA)/MCD2-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-Q(H)/MCD2-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
RZA250D
RZA
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.44 | 4.10 | 22.00 | 12.10 | |||
|
AL-H12/4DR3HD1(U) / AUMD-H12/4DR3HB2
M-Ducted
|
AUX | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
RXYL35M-T1B/FDMD35M-B
M-Ducted
|
AUX | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
FUJITSU | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOHG90LRLA/ARHG90LHTA
AOHG**L
|
GENERAL | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
42QTD036D8S*/38QUS036D8S*
Cassette
|
CARRIER | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
42HK36VDS8C/38HU36VDS8C
Cassette
|
CIAT | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
KC210HIDS8/AIC210HIDS8
Cassette
|
RIELLO | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
UUC1 U40 / CM24F N10
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40TK / ZBNW24GM1A1
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / CM24F N11
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
MOX230-12HFN8-QRD0W(GA)/MCA3U-12HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-Q(GA)/MCA3U-12HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
KUE-35 DVR13/KCI-35 DR14
ZEN Cassette
|
KAYSUN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7CRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QRD0W(GA)-GR/MCA3U-12HRFNX-QRD0W(GA)-GR
Cassette R32
|
MIDEA | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
YUKF12BYEEBMO-1/YKKF12BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
RZASG100MY1 / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | 3.71 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | 3.71 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | -10° | 9.50 | 6.00 |