Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(33)
ATLANTIC
(4)
AUX
(22)
BOSCH
(32)
BRYANT
(0)
Buderus
(3)
CARRIER
(43)
CIAT
(24)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(386)
EQUATION
(0)
FUJI ELECTRIC
(77)
FUJITSU
(201)
Fujitsu Atlantic
(104)
GENERAL
(104)
GREE
(12)
GSS
(0)
HAIER
(175)
HEC
(0)
HEIWA
(0)
HISENSE
(70)
HITACHI
(72)
IVT
(2)
Inventor
(34)
KAYSUN
(46)
LG
(119)
MIDEA
(215)
MITSUBISHI ELECTRIC
(301)
Mitsubishi Heavy Industries
(184)
NORD
(19)
Nobu
(0)
PANASONIC
(82)
RIELLO
(24)
Rotenso
(6)
SAMSUNG
(61)
THERMOR
(12)
TOSHIBA
(92)
Viessmann
(16)
Vulcano
(0)
WESTPOINT
(0)
YORK
(18)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEG45KBTB/ARXG45KHTB
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
PUZ-M125YKA2/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.89 | 4.13 | 3.71 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA2/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.89 | 4.13 | 3.71 | -15° | 12.10 | 8.50 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG30KATA/RDG30KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXG30KMLA
ARXG**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
PUZ-ZM250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA3/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
YUKF42BYEEBMO-1/YKKF42BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -15° | 12.10 | 9.50 | |
|
MOX630U-48HFN8-QRD0W(GA)/MCD1-48HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MCD-48NX
Cassette R32
|
MIDEA | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KCIS-140 DR14
Zen
|
KAYSUN | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
42QTD048D8S/38QUS048D8S
Cassette
|
CARRIER | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-Q(H)/MCD2-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
SUZ-SM35VA2/PEAD-SM35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.70 | |
|
AL-H36/4DR3C3(U) / AUCA-H36/4DR3HB2
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCA105Q-B
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
RXM50A9 / FNA50A9
RXM
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.09 | 3.33 | -10° | 5.00 | 4.00 | |
|
AD125S2SM3FA/1U125S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.96 | 3.31 | 12.40 | 8.00 | ||
|
AB140S2SR1FA(H)/1U140S2SP2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.99 | 3.06 | 13.60 | 10.00 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOHG72LRLA/ARHG72LHTA
AOHG**L
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
ROG72LRLA/RDG72LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
ADH140H1ERG/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.84 | 3.94 | 3.31 | 13.40 | 8.50 | ||
|
U-140PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.37 | 3.60 | 3.76 | -15° | 13.40 | 9.50 | |
|
UUA1 UL0 / CT09F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / CT12F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 3.40 | 2.80 | |
|
U-140PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.39 | 3.60 | 3.76 | -15° | 13.40 | 9.50 | |
|
FDC100VNA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
AD71S2SM9FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.06 | 4.00 | 3.34 | -10° | 6.80 | 5.00 | |
|
SUZ-SM35VA/PEAD-SM35JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
SUZ-SM35VA/PEAD-SM35JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
2MXM50A9 / FDXM25F9 / FDXM25F9
2MXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 3.80 | 3.66 | -15° | 5.00 | 4.20 |