Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(33)
ATLANTIC
(4)
AUX
(22)
BOSCH
(32)
BRYANT
(0)
Buderus
(3)
CARRIER
(43)
CIAT
(24)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(386)
EQUATION
(0)
FUJI ELECTRIC
(77)
FUJITSU
(201)
Fujitsu Atlantic
(104)
GENERAL
(104)
GREE
(12)
GSS
(0)
HAIER
(175)
HEC
(0)
HEIWA
(0)
HISENSE
(70)
HITACHI
(72)
IVT
(2)
Inventor
(34)
KAYSUN
(46)
LG
(119)
MIDEA
(215)
MITSUBISHI ELECTRIC
(301)
Mitsubishi Heavy Industries
(184)
NORD
(19)
Nobu
(0)
PANASONIC
(82)
RIELLO
(24)
Rotenso
(6)
SAMSUNG
(61)
THERMOR
(12)
TOSHIBA
(92)
Viessmann
(16)
Vulcano
(0)
WESTPOINT
(0)
YORK
(18)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG60A / FCAG60B
RZAG
|
DAIKIN | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.25 | 3.40 | -20° | 6.00 | 4.60 | |
|
FDC125VSA/FDT125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.38 | 3.74 | 12.50 | 9.80 | ||
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
GUD35T1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.20 | -10° | 3.50 | 3.10 | ||
|
RZAG71NV1 / FBA35A9 / FBA35A9
RZAG
|
DAIKIN | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.46 | 4.10 | 4.10 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FBA35A9 / FBA35A9
RZAG
|
DAIKIN | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.46 | 4.10 | 4.10 | -10° | 6.80 | 4.70 | |
|
ADH140H1ERG/1U140S2SP2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.18 | 4.10 | 3.72 | 13.60 | 10.00 | ||
|
RZAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -10° | 5.00 | 4.30 | |
|
UUD1 U30 / UT36F NY0
UU
|
LG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.90 | -10° | 11.00 | 9.00 | |
|
UUD3 U30 / UT36F NY0
UU
|
LG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.90 | -10° | 11.00 | 9.00 | |
|
SUZ-M35VA/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.71 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.71 | -10° | 3.50 | 2.70 | |
|
ND125MGAHRA/1N125TEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 2.95 | 12.50 | 9.60 | ||
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
UUD1 U30 / UM48FH N30
UU
|
LG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | 13.40 | 9.50 | ||
|
UUD3 U30 / UM48FH N30
UU
|
LG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | 13.40 | 9.50 | ||
|
FDC100VNA-W/FDTC50VH/FDTC50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.38 | 3.67 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDTC50VH/FDTC50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.38 | 3.67 | -20° | 10.00 | 8.50 | |
|
RAV-GM302ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.13 | 4.57 | 4.47 | -15° | 2.50 | 2.30 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
FDC125VNA-W/FDT125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.90 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDT125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.90 | 12.50 | 9.80 | ||
|
ND105MFAHRA/1N105XEAFRA
NORD - MSP Duct
|
NORD | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.20 | -10° | 9.50 | 7.80 | |
|
ND105MFAHRA/1N105XEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.20 | -10° | 9.50 | 7.80 | |
|
PUZ-M100YKA2/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PEAD-M100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA2/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PEAD-M100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PEAD-M100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PEAD-M100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.80 | -15° | 9.50 | 8.00 | |
|
RZAG50B / FBA50A9
RZAG
|
DAIKIN | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.80 | -10° | 5.00 | 4.30 | |
|
RXM50R / FCAG50B
RXM
|
DAIKIN | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.30 | 3.70 | -15° | 5.00 | 4.36 | |
|
RXM50A / FCAG50B
RXM
|
DAIKIN | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.30 | 3.70 | -15° | 5.00 | 4.36 | |
|
42QSS030D8S*/38QUS030D8S*
Ducted
|
CARRIER | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
DC280HIDS8/AIC280HIDS8
Ducted
|
RIELLO | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
FDC125VNA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
GUD71T1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | -10° | 7.10 | 5.00 | ||
|
RXM35R9 / FBA35A9
RXM
|
DAIKIN | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.07 | 4.02 | -15° | 3.40 | 2.90 | |
|
RAC-VJ35NHAE / RAI-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.78 | |
|
FDC250VSA-W/FDT125VH/FDT125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.35 | 3.80 | 25.00 | 14.20 | ||
|
AOYG18KBTB/ARXG18KLLAP
ARY**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ARXG18KLLAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
ROG18KBTB/RDG18KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 |