Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(24)
ATLANTIC
(4)
AUX
(20)
BOSCH
(21)
BRYANT
(0)
Buderus
(3)
CARRIER
(34)
CIAT
(19)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(342)
DE DIETRICH
(2)
EQUATION
(0)
FUJI ELECTRIC
(61)
FUJITSU
(187)
Fujitsu Atlantic
(88)
GENERAL
(81)
GREE
(6)
GSS
(0)
HAIER
(172)
HEC
(0)
HEIWA
(0)
HISENSE
(52)
HITACHI
(55)
IVT
(2)
Inventor
(26)
KAYSUN
(29)
LG
(89)
MIDEA
(119)
MITSUBISHI ELECTRIC
(211)
Mitsubishi Heavy Industries
(164)
NORD
(13)
Nobu
(0)
PANASONIC
(71)
PITSOS
(0)
RIELLO
(19)
Rotenso
(3)
SAMSUNG
(34)
THERMOR
(8)
TOSHIBA
(74)
Viessmann
(13)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(13)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG125NY1 / FBA125A
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.18 | 4.18 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.18 | 4.18 | 13.40 | 9.52 | ||
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.20 | 19.00 | 11.20 | |||
|
U-140PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.97 | 4.14 | 3.33 | -20° | 13.40 | 9.50 | |
|
U-140PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.97 | 4.14 | 3.33 | -20° | 13.40 | 9.50 | |
|
RAV-GM802ATW-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.30 | 3.77 | -15° | 6.70 | 5.10 | |
|
RZAG125NV1 / FDA125A
RZAG
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.35 | 12.10 | 9.52 | |||
|
RAV-GM1102ATW-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.91 | -15° | 9.50 | 8.00 | |
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RZAG125NV1 / FBA125A
RZAG
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
UUC1 U40 / UM30FH N20
U4
|
LG | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.97 | -10° | 7.90 | 5.40 | |
|
PUZ-ZM125VDA/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
ND50MDAHRA/1N50KEAFRA
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
ND50MDAHRA/1N50KEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
PUZ-ZM140YDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC90VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
FDC90VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
PUZ-ZM140YDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
PUZ-ZM71VHA2/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA2/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
PUZ-ZM140VDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC100VNA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.19 | 12.10 | 9.52 |