Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(64)
ATLANTIC
(34)
AUX
(131)
BOSCH
(120)
BRYANT
(6)
Buderus
(38)
CARRIER
(129)
CIAT
(27)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(574)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(116)
FUJITSU
(282)
Fujitsu Atlantic
(151)
GENERAL
(202)
GREE
(126)
GSS
(4)
HAIER
(448)
HEC
(5)
HEIWA
(8)
HISENSE
(377)
HITACHI
(110)
IVT
(10)
Inventor
(113)
KAYSUN
(46)
LG
(280)
MIDEA
(664)
MITSUBISHI ELECTRIC
(395)
Mitsubishi Heavy Industries
(204)
NORD
(44)
Nobu
(8)
PANASONIC
(259)
PITSOS
(6)
RIELLO
(29)
Rotenso
(3)
SAMSUNG
(152)
THERMOR
(54)
TOSHIBA
(215)
Viessmann
(13)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(24)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
2AMW42U4RGC/HB20XU0BG/HB20XU0BG
Uni HB
|
HISENSE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.42 | 4.00 | 4.60 | -10° | 4.00 | 3.00 | |
|
2AMW42U4RGC/HA20XU00G/HA20XU00G
Uni HA
|
HISENSE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.42 | 4.00 | 4.60 | -10° | 4.00 | 3.00 | |
|
CU-UZ25WKE / CS-UZ25WKE
2019
|
PANASONIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 4.05 | -15° | 2.50 | 1.90 | |
|
NAGANO GAINABLE MP IG95MP-NG / E1U90LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.49 | -10° | 9.50 | 7.20 | |
|
GWH24AGDXE-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.95 | -10° | 6.20 | 4.70 | |
|
GWH24ALEXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 6.20 | 4.70 | |
|
PUZ-M250YDA/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.59 | 3.30 | -20° | 22.00 | 17.00 | |
|
M3OA-18HFN8-Q/MSCB1BU-09HRFN8-QRD1GW+MSCB1BU-09HRFN8-QRD1GW
M3OA-18HFN8-Q
|
MIDEA | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.10 | -10° | 5.30 | 4.30 | |
|
AM2-H18/4DR3C+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -10° | 5.30 | 4.50 | |
|
GWH12AZCXB-K6DNA3Z
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.80 | -10° | 3.20 | 2.80 | |
|
FDC140VSX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
GWH09AGAXB-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
WIZO-09225.MH / WIZ-09225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
HDLE-025N-09M25/YDAE-025R-09M25
Aura V2
|
AIRWELL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
GWH09AWAXB-K6DNA4F
MONOSPLITS
|
GREE | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
CU-TZ71WKE / CS-TZ71WKEW
2019
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.51 | -15° | 7.10 | 5.50 | |
|
RAC-DJ70WHAE / RAK-DJ70RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.10 | -15° | 7.10 | 5.40 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.47 | -10° | 14.19 | 12.40 | |
|
SRC25ZSP-W1/SRK25ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 4.05 | -10° | 2.50 | 2.70 | |
|
PUZ-M125VKA2/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA2/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
RZAG60A / FDXM60F9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
RZAG60A / FNA60A9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
RAV-GM1601ATP-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.40 | -10° | 14.10 | 12.10 | |
|
AD140S2SM3FA/1U140S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | 13.40 | 11.00 | ||
|
RPIH-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.70 | 3.35 | -10° | 12.50 | 9.00 | |
|
2AMW35U4RGC/HB20XU0AG/HB20XU0AG
Uni HB
|
HISENSE | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 4.00 | 4.70 | -10° | 3.50 | 3.00 | |
|
2AMW35U4RGC/HB20XU0BG/HB20XU0BG
Uni HB
|
HISENSE | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 4.00 | 4.70 | -10° | 3.50 | 3.00 | |
|
2AMW35U4RGC/HA20XU00G/HA20XU00G
Uni HA
|
HISENSE | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 4.00 | 4.70 | -10° | 3.50 | 3.00 | |
|
AD140S2SM3FA/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
MOX230-12HFN8-QRD0W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-1
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KSD-35 DR14-2
ZEN Console
|
KAYSUN | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
XDMX-035N-09M25/YDAX-035H-09M25
XDMX
|
AIRWELL | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 |