Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(57)
ATLANTIC
(34)
AUX
(121)
BOSCH
(110)
BRYANT
(6)
Buderus
(36)
CARRIER
(107)
CIAT
(16)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(344)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(72)
FUJITSU
(149)
Fujitsu Atlantic
(82)
GENERAL
(133)
GREE
(126)
GSS
(4)
HAIER
(357)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(75)
IVT
(10)
Inventor
(98)
KAYSUN
(30)
LG
(216)
MIDEA
(635)
MITSUBISHI ELECTRIC
(227)
Mitsubishi Heavy Industries
(104)
NORD
(34)
Nobu
(8)
PANASONIC
(217)
PITSOS
(6)
RIELLO
(18)
Rotenso
(2)
SAMSUNG
(129)
THERMOR
(49)
TOSHIBA
(170)
Viessmann
(6)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(17)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS71REBHRA-RBS/1U71WS3FRA
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MWV/1U71WEAFRA-SH
Serene
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-S/1U71WS3FRA
Serene
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
MUZ-LN50VG2/MSZ-LN50VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
MUZ-LN50VG3/MSZ-LN50VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
CLC8001i 35 E / CLC8001i-W 35 E
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
MU2R17 U13 / MJ07PC NSJ / MJ09PC NSJ
MU
|
LG | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.61 | 4.25 | -15° | 4.69 | 3.60 | |
|
2AMXM50M9 / ATXM25R / ATXM25R
2AMXM
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25A / ATXM25A
2AMXM
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2MXM50A9 / FTXM25R / FTXM25R
2MXM
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.53 | 4.61 | 4.08 | -10° | 5.00 | 4.20 | |
|
42QHP009E8SH*/38QHP009E8SH*
Wall mounted
|
CARRIER | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.43 | -10° | 2.70 | 2.90 | |
|
42QHP012E8SH*/38QHP012E8SH*
Wall mounted
|
CARRIER | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.43 | -10° | 3.60 | 2.90 | |
|
THRVO-09/THRVI-09WFI
Thora
|
Inventor | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.40 | -10° | 2.70 | 2.90 | |
|
MOX330-09HFN8-QRE1GW/MSOPBU-09HRFN8-QRE1GW
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.40 | -10° | 2.70 | 2.90 | |
|
MOX330-09HFN8-OPP/MSOPP-09HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.40 | -10° | 2.70 | 2.90 | |
|
MOX330-09HFN8-OPP/MSOPP-09HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.40 | -10° | 2.70 | 2.90 | |
|
RXJ25A / FTXJ25AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A / FTXJ25AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A / FTXJ25AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXA25A8 / FTXA25CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXA25A8 / FTXA25CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXA25A8 / FTXA25CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXA25A8 / FTXA25CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXA25A8 / FTXA25CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXA25A8 / FTXA25CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A9 / FTXJ25AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A9 / FTXJ25AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A9 / FTXJ25AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A9 / FTXJ25AW9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A9 / FTXJ25AB9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
RXJ25A9 / FTXJ25AS9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -10° | 2.50 | 2.45 | |
|
MUZ-AY50VG/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VG2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY35VG/MSZ-AY35VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUZ-AY35VG2/MSZ-AY35VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
AJ050TXJ2KG / AR70F09CAAW / AR70F09CAAW
FJM
|
SAMSUNG | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.54 | 4.64 | 4.38 | -10° | 5.00 | 4.21 | |
|
MUZ-AY25VGH/MSZ-AY25VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.10 | -20° | 2.50 | 2.40 | |
|
MUZ-AY25VGH2/MSZ-AY25VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.10 | -20° | 2.50 | 2.40 | |
|
RXJ20A / FTXJ20AB
RXJ
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A / FTXJ20AS
RXJ
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A / FTXJ20AW
RXJ
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CB
RXA
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CS
RXA
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CW
RXA
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CS
RXA
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CB
RXA
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CW
RXA
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 |