Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(36)
ATLANTIC
(8)
AUX
(28)
BOSCH
(32)
BRYANT
(0)
Buderus
(3)
CARRIER
(53)
CIAT
(30)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(498)
DE DIETRICH
(2)
EQUATION
(0)
FUJI ELECTRIC
(94)
FUJITSU
(255)
Fujitsu Atlantic
(123)
GENERAL
(116)
GREE
(12)
GSS
(0)
HAIER
(229)
HEC
(0)
HEIWA
(0)
HISENSE
(75)
HITACHI
(86)
IVT
(2)
Inventor
(42)
KAYSUN
(46)
LG
(141)
MIDEA
(215)
MITSUBISHI ELECTRIC
(344)
Mitsubishi Heavy Industries
(248)
NORD
(19)
Nobu
(0)
PANASONIC
(103)
PITSOS
(0)
RIELLO
(30)
Rotenso
(6)
SAMSUNG
(72)
THERMOR
(12)
TOSHIBA
(121)
Viessmann
(20)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(22)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM1102ATW-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.91 | -15° | 9.50 | 8.00 | |
|
FDC100VNA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.26 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.41 | -20° | 10.00 | 8.50 | |
|
RAV-GM1102ATW-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.40 | 3.92 | -15° | 9.50 | 8.00 | |
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RZAG125NV1 / FBA125A
RZAG
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.56 | 4.37 | 12.10 | 9.52 | |||
|
UUC1 U40 / UM30FH N20
U4
|
LG | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.97 | -10° | 7.90 | 5.40 | |
|
PUZ-ZM125VDA/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
RZAG125NY1 / FCAHG125H
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.02 | 4.53 | 12.10 | 9.52 | |||
|
ND50MDAHRA/1N50KEAFRA
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
ND50MDAHRA/1N50KEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
PUZ-ZM140YDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC90VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
U-50PZ3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.94 | -15° | 4.70 | 4.00 | |
|
AUW71U4RK8/ACT71UR4RJC8
Turbo Inverter R32
|
HISENSE | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.80 | -10° | 7.00 | 5.50 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
FDC90VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.22 | 4.55 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.56 | 4.74 | -15° | 9.00 | 6.00 | |
|
PUZ-ZM140YDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
RZAG100NV1 / FCAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.64 | 4.64 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FCAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.64 | 4.64 | -10° | 9.50 | 7.80 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
RZAG125NV1 / FCAHG125H
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.02 | 4.53 | 12.10 | 9.52 | |||
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
U-71PZ3E5A / S-6071PU3E
2021
|
PANASONIC | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 4.23 | -15° | 7.10 | 5.20 | |
|
PUZ-ZM71VHA2/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA2/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
RZAG35A / FCAG35B
RZAG
|
DAIKIN | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.30 | -20° | 3.50 | 3.30 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 |