Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(64)
ATLANTIC
(34)
AUX
(131)
BOSCH
(120)
BRYANT
(6)
Buderus
(38)
CARRIER
(129)
CIAT
(27)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(574)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(116)
FUJITSU
(282)
Fujitsu Atlantic
(151)
GENERAL
(202)
GREE
(126)
GSS
(4)
HAIER
(448)
HEC
(5)
HEIWA
(8)
HISENSE
(377)
HITACHI
(110)
IVT
(10)
Inventor
(113)
KAYSUN
(46)
LG
(280)
MIDEA
(664)
MITSUBISHI ELECTRIC
(395)
Mitsubishi Heavy Industries
(204)
NORD
(44)
Nobu
(8)
PANASONIC
(259)
PITSOS
(6)
RIELLO
(29)
Rotenso
(3)
SAMSUNG
(152)
THERMOR
(54)
TOSHIBA
(215)
Viessmann
(13)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(24)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG14KBTB/ARXG14KHTAP
ARH**K
|
GENERAL | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
ROG14KBTB/RDG14KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KHTAP
ARXG**K
|
FUJITSU | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXG14KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
2MXF40A / FTXF20B / FTXF20B
2MXF
|
DAIKIN | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 4.10 | -15° | 4.00 | 3.20 | |
|
2MXF40A / CTXF20F / CTXF20F
2MXF
|
DAIKIN | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 4.10 | -15° | 4.00 | 3.20 | |
|
4AMW81U4RJC/HB35XU0AG/HB50XU0AG
Uni HB
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.87 | 4.12 | 3.40 | -10° | 7.50 | 6.50 | |
|
4AMW81U4RJC/HB35XU0BG/HB50XU0BG
Uni HB
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.87 | 4.12 | 3.40 | -10° | 7.50 | 6.50 | |
|
4AMW81U4RJC/HA35XU00G/HA50XU00G
Uni HA
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.87 | 4.12 | 3.40 | -10° | 7.50 | 6.50 | |
|
FDC125VNA-W/FDU125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDUM125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDU125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDUM125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
4AMW72U4RJC/HA20XU00G/HA50XU00G
Uni HA
|
HISENSE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.88 | 4.12 | 3.40 | -10° | 7.20 | 6.50 | |
|
4AMW72U4RJC/HB20XU0AG/HB50XU0AG
Uni HB
|
HISENSE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.88 | 4.12 | 3.40 | -10° | 7.20 | 6.50 | |
|
4AMW72U4RJC/HB20XU0BG/HB50XU0BG
Uni HB
|
HISENSE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.88 | 4.12 | 3.40 | -10° | 7.20 | 6.50 | |
|
AD105S2SM3FA/1U105S2SS1FB
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM3FA(H)/1U105S2SS1FB
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
AD105S2SM9FA(H)/1U105S2SS1FB
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.20 | 3.50 | -10° | 9.50 | 6.00 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
PUZ-ZM100YDA/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -20° | 9.50 | 7.80 | |
|
MUZ-BT35VG2/MSZ-BT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.50 | |
|
RXM50A9 / FBA50A9
RXM
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.27 | 4.06 | 3.82 | -10° | 5.00 | 4.40 | |
|
CU-2TZ50TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.35 | -15° | 5.00 | 4.50 | |
|
U-71PZ3E5A / S-6071PF3E
2021
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 4.00 | -15° | 6.80 | 4.70 | |
|
CU-Z60CBEA / CS-Z60CD3EAW
2025
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
MXZ-2D53VAH2/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.76 | -20° | 5.30 | 4.50 | |
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
U-36PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 4.62 | -15° | 3.60 | 2.80 | |
|
CU-RZ25CKE / CS-RZ25CKEW
2025
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
GWH12ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.20 | -10° | 3.20 | 2.80 | |
|
42HY48VDS8C/38HU48VDT8C
Ducted
|
CIAT | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
42QSS048D8S*/38QUS048D8T*
Ducted
|
CARRIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
DC213HIDS8/AIC213HIDT8
Ducted
|
RIELLO | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
RPIL-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.05 | 3.74 | -15° | 6.90 | 6.00 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AUW105U4RK7/AUD105UX4RQM8
Super Inverter R32
|
HISENSE | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
AS25PBPHRA-PRE/1U25YEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
AS25PBPHRA-PRE/1U25YEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
UI 2,7 kW MURAO SMART BLANC & UE MONO 2,7 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
MOD30U-42HFN8-QRD0W(GA)/MTJ-42HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
MOD30U-42HFN8-Q(GA)/MTJ-42HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
MO-42N8-Q/MTJ-42NX
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 |