Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(55)
ATLANTIC
(38)
AUX
(127)
BOSCH
(105)
BRYANT
(6)
Buderus
(36)
CARRIER
(117)
CIAT
(22)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(456)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(89)
FUJITSU
(203)
Fujitsu Atlantic
(101)
GENERAL
(145)
GREE
(120)
GSS
(4)
HAIER
(408)
HEC
(5)
HEIWA
(8)
HISENSE
(348)
HITACHI
(83)
IVT
(10)
Inventor
(106)
KAYSUN
(20)
LG
(238)
MIDEA
(568)
MITSUBISHI ELECTRIC
(270)
Mitsubishi Heavy Industries
(168)
NORD
(34)
Nobu
(8)
PANASONIC
(238)
PITSOS
(6)
RIELLO
(24)
Rotenso
(0)
SAMSUNG
(140)
THERMOR
(49)
TOSHIBA
(199)
Viessmann
(10)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(19)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GWH24ATEXF-K6DNA3A
MONOSPLITS
|
GREE | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
GWH24AGE-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
GWH24AGE-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
CU-Z71ZKE / CS-Z71ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 | |
|
CU-Z71CKE / CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 | |
|
AR50F15C1AHN/AR50F15C1AHX
RAC
|
SAMSUNG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 3.47 | -11° | 4.30 | 2.70 | |
|
SRC35ZTL-W/SRK35ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.70 | 4.22 | -10° | 3.50 | 2.80 | |
|
RZAG60B / FTXM60A
RZAG
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.35 | 3.61 | -10° | 6.00 | 4.60 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
AS35PCHHRA-NR/1U35KEFFRA-NR
Pearl Nordic
|
HAIER | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.50 | -10° | 3.50 | 3.90 | |
|
MU5R36 U36A0 / MJ18PC NSK0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.15 | 3.25 | -10° | 9.20 | 6.80 | |
|
PUZ-M100YKA2/PCA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PCA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PCA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PCA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
AC105S2SH2FA(H)/1U105S2SQ1FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
YDAM-100R-09M22/FDHM-100N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
AS105PFAHRA/1U105XEAFRA
HAIER - QUARTZ
|
HAIER | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AS105PFAHRA/1U105XEAFRA-H
Quartz
|
HAIER | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 9.50 | 7.60 | |
|
AOEH09KNCA/ASEH09KNCA
ASE**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOHH09KNCA/ASHH09KNCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOYH09KNCA/ASYH09KNCA
ASY**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
ROH09KNCA/RSH09KNCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOHH09KNCA/ASHH09KNCH
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOYH09KNCA/ASYH09KNCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AS 018 NBB.UI/1U 018 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.00 | -10° | 5.20 | 4.60 | |
|
RAV-GM801ATP-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.21 | 3.62 | -15° | 6.90 | 5.10 | |
|
CU-RZ35CKE / CS-RZ35CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
M4OA-27HFN8-Q(HRU)/MSCB1BU-09HRFN8-QRD1GW+MSCB1CU-18HRFN8-QRD1GW
M4OA-27HFN8-Q(HRU)
|
MIDEA | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -10° | 7.90 | 6.20 | |
|
CU-TZ60WKE / CS-TZ60WKEW
2019
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.68 | -15° | 6.00 | 4.40 | |
|
CU-TZ60ZKE / CS-TZ60ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.72 | -15° | 6.00 | 4.40 | |
|
CU-3Z52CBE / CS-Z42CKEW / CS-Z42CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.12 | -15° | 5.20 | 5.20 | |
|
RAS-5HVRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
GWH18AKCXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 4.00 | -10° | 5.30 | 4.20 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
AR70F24C1AWN/AR70F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1AWN/AR60F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24CAAWN/AR60F24CAAWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1KWN/AR60F24C1KWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR70F24C1DBN/AR70F24C1DBX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR80F24CAAWN/AR80F24CAAWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR70H24C1AWN/AR70H24C1AWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.73 | -11° | 6.50 | 4.10 | |
|
AR80H24CAAWN/AR80H24CAAWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR70H24CACBN/AR70H24CACBX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR70H24CACWN/AR70H24CACWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
SCM41ZS-W/SRK20ZS-WF/SRK20ZS-WF
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.40 | 4.50 | 4.41 | -10° | 4.00 | 3.40 | |
|
RAV-GM902ATW-E/RAV-HM901KRTP-E
DI
|
TOSHIBA | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.30 | -15° | 8.00 | 6.30 | |
|
GWHD(28)NK6OO GWH09AGCXB-K6DNA1G/I+GWH18AGD-K6DNA1E/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.53 | -10° | 8.00 | 6.60 | |
|
AJ050HCJ2KG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.46 | 4.21 | 4.15 | -10° | 5.00 | 4.21 |