Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(21)
ATLANTIC
(0)
AUX
(14)
BOSCH
(21)
BRYANT
(0)
Buderus
(3)
CARRIER
(24)
CIAT
(13)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(99)
HEC
(0)
HEIWA
(0)
HISENSE
(40)
HITACHI
(41)
IVT
(2)
Inventor
(18)
KAYSUN
(29)
LG
(67)
MIDEA
(119)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(13)
Nobu
(0)
PANASONIC
(50)
RIELLO
(13)
Rotenso
(3)
SAMSUNG
(23)
THERMOR
(8)
TOSHIBA
(45)
Viessmann
(9)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ROG14KBTB/RDG14KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXG45KHTAP
ARX**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KBTB/RDG45KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTAP
ARXG**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.80 | 3.32 | -10° | 20.00 | 11.40 | |
|
AD125S2SM3FA/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
PUZ-SM100YKA2/PEAD-SM100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA2/PEAD-SM100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA2/PEAD-SM100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PEAD-SM100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PEAD-SM100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PEAD-SM100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PEAD-SM100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PEAD-SM100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
RXM50R / FDXM50F9
RXM
|
DAIKIN | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -15° | 5.00 | 4.00 | |
|
RXM50A / FDXM50F9
RXM
|
DAIKIN | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -15° | 5.00 | 4.00 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 | |
|
U-200PZH4E8 / S-200PE4E
2024
|
PANASONIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.02 | 3.85 | 3.55 | 19.00 | 14.50 | ||
|
AOYG24KATA/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RDG24KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOHG24KATA/ARXG24KMLA
ARXG**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ARXG24KMLA
ARXG**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ARXG24KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
SRC50ZSX-W3/FDUM50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.89 | 3.39 | -20° | 5.00 | 3.70 | |
|
PUZ-M250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.39 | 3.56 | 3.30 | -20° | 22.00 | 20.20 | |
|
AF42S2SD1FA/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF42S2SD1FA(H)/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF42S2SD1FA(D)/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
NAGANO CONSOLE IC42V3-NG / E1U42L-NG
NAGANO CONSOLE
|
THERMOR | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AOYG36KATA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KATA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 |