Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(101)
HEC
(0)
HEIWA
(0)
HISENSE
(41)
HITACHI
(44)
IVT
(0)
Inventor
(15)
KAYSUN
(26)
LG
(64)
MIDEA
(96)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
RIELLO
(11)
Rotenso
(3)
SAMSUNG
(23)
THERMOR
(5)
TOSHIBA
(45)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX330U-18HFN8-Q(H)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CU-Z35CBEA / CS-Z35CD3EAW
2025
|
PANASONIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.82 | -15° | 3.50 | 2.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.39 | 12.10 | 6.00 | |||
|
PUZ-ZM35VKA2/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
FDC100VNA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
AD50S2SS1FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.73 | -10° | 5.00 | 4.30 | |
|
UUB1 U20 / UM18FH NA0
UU
|
LG | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -10° | 5.00 | 4.40 | |
|
AD71S2SS1FA(H)/1U71S2SR3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.73 | -10° | 7.10 | 5.00 | |
|
AUD140UX4REH8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.27 | 3.18 | -10° | 13.50 | 9.00 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.10 | 19.00 | 11.20 | |||
|
FDC280VSA-W/FDUM140VH/FDUM140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.23 | 3.54 | 27.00 | 16.00 | ||
|
RAS-5HVRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
SRC60ZSX-W3/SRR60ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.30 | 3.54 | -10° | 5.60 | 5.20 | |
|
PUZ-ZM35VKA2/PEAD-M35JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
RAS-4HVNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
GUD100PHS1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | -10° | 10.50 | 7.00 | ||
|
GUD100PHS1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | -10° | 10.50 | 7.00 | ||
|
38HM18VS8C-2/42HY09VS8C*
Ducted
|
CIAT | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
38QUS018D8S2-2/42QSS009D8S*
Ducted
|
CARRIER | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
AIX250HIM8-2/DC225HIM8*
Ducted
|
RIELLO | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
FDC71VNX-W/FDUM40VH/FDUM40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.15 | 4.44 | -20° | 7.10 | 6.00 | |
|
PUZ-SM125YKA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
RZAG100NV1 / FBA50A9 / FBA50A9
RZAG
|
DAIKIN | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.12 | 4.12 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FBA50A9 / FBA50A9
RZAG
|
DAIKIN | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.12 | 4.12 | -10° | 9.50 | 7.80 | |
|
RAV-GP561ATW-E/RAV-HM561BTP-E
SDI
|
TOSHIBA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.81 | 4.27 | 3.48 | -27° | 5.00 | 3.80 | |
|
M4OA-27HFN8-Q(HRU)/MTJ-09HWFNX-QRD1W(GA)+MTJ-18HWFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.90 | 6.30 | |
|
AD105S2SM3FA(H)/1U105S2SS2FA
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.50 | -10° | 9.50 | 7.20 | |
|
AOEG24KBTB/ARXH24KMTAP
ARXH**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
PUZ-ZM100VDA/PEAD-M50JA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PEAD-M50JAL2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 |