Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(88)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
HITACHI
(44)
IVT
(0)
Inventor
(15)
KAYSUN
(26)
LG
(64)
MIDEA
(96)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
RIELLO
(11)
Rotenso
(3)
SAMSUNG
(23)
THERMOR
(5)
TOSHIBA
(45)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-M250YDA/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.59 | 3.30 | -20° | 22.00 | 17.00 | |
|
PUZ-M125VKA2/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA2/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.54 | 3.88 | 3.61 | -15° | 12.10 | 8.50 | |
|
RZAG60A / FDXM60F9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
RZAG60A / FNA60A9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
RAV-GM1601ATP-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.40 | -10° | 14.10 | 12.10 | |
|
AD140S2SM3FA/1U140S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | 13.40 | 11.00 | ||
|
RPIH-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.70 | 3.35 | -10° | 12.50 | 9.00 | |
|
AD140S2SM3FA/1U140S2SN1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 3.93 | 3.05 | 13.40 | 8.50 | ||
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG14KBTB/ARXG14KLLAP
ARH**K
|
GENERAL | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
ROG14KBTB/RDG14KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXG45KHTAP
ARX**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KBTB/RDG45KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTAP
ARXG**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.80 | 3.32 | -10° | 20.00 | 11.40 | |
|
AD125S2SM3FA/1U125S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.93 | 3.23 | 12.30 | 8.00 | ||
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
PUZ-SM100YKA2/PEAD-SM100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA2/PEAD-SM100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA2/PEAD-SM100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PEAD-SM100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PEAD-SM100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PEAD-SM100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PEAD-SM100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PEAD-SM100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 |