Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(21)
ATLANTIC
(0)
AUX
(14)
BOSCH
(21)
BRYANT
(0)
Buderus
(3)
CARRIER
(25)
CIAT
(13)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(270)
DE DIETRICH
(2)
EQUATION
(0)
FUJI ELECTRIC
(47)
FUJITSU
(142)
Fujitsu Atlantic
(72)
GENERAL
(72)
GREE
(7)
GSS
(0)
HAIER
(126)
HEC
(0)
HEIWA
(0)
HISENSE
(51)
HITACHI
(48)
IVT
(2)
Inventor
(30)
KAYSUN
(30)
LG
(71)
MIDEA
(135)
MITSUBISHI ELECTRIC
(222)
Mitsubishi Heavy Industries
(167)
NORD
(13)
Nobu
(0)
PANASONIC
(50)
PITSOS
(0)
RIELLO
(14)
Rotenso
(3)
SAMSUNG
(30)
THERMOR
(8)
TOSHIBA
(69)
Viessmann
(9)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG71NY1 / FNA35A9 / FNA35A9
RZAG
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.14 | 4.14 | -10° | 6.80 | 4.70 | |
|
SUZ-M50VA/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.10 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.10 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.10 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.10 | -10° | 5.00 | 4.30 | |
|
AOYG18KBTB/ARXG18KHTAP
ARY**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ARXG18KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
ROG18KBTB/RDG18KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXG18KHTAP
ARXG**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ARXG18KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.32 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.32 | 4.10 | 4.10 | 19.00 | 11.20 | ||
|
AOYG36KBTB/ARXG36KHTAP
ARY**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/ARXG36KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
ROG36KBTB/RDG36KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXG36KHTAP
ARXG**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RDG36KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KHTAP
ARXG**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOEG36KRTA/ARXG36KHTAP
ARXG**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ARXG36KHTAP
ARXG**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOYG36KBTB/ARXG36KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXG36KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
SRC50ZSX-W3/SRF50ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 5.00 | 4.10 | |
|
FDC90VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
RZAG50A / FBA50A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.80 | -20° | 5.00 | 4.30 | |
|
MOX230-12HFN8-QRD0W(GA)/MTJ-12HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MTJU-12HNX
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KPD-35 DR15
Duct R32
|
KAYSUN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
DDMD-035N-09M25/YDAX-035H-09M25**
DDMD
|
AIRWELL | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
42QSV012D8S*/38QUS012D8S-1
Ducted
|
CARRIER | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7iDI-12WiFiR
Ducted R32
|
Inventor | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
RXM50R / FVXM50A9
RXM
|
DAIKIN | Floor standing | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.81 | -15° | 5.00 | 4.10 | |
|
5MWXM90A9 / FBA125A
5MWXM
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.14 | 4.02 | -15° | 9.00 | 6.46 | |
|
RZAG71NV1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RXM50A8 / FVXM50B
RXM
|
DAIKIN | Floor standing | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.26 | 3.72 | -20° | 5.00 | 4.10 | |
|
U-50PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.61 | -20° | 5.00 | 4.00 | |
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
RAV-GP1101AT8-E/RAV-HM1101BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.19 | 4.06 | -20° | 10.00 | 10.80 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.10 | 22.00 | 12.10 | |||
|
U-250PZH4E8 + P‐VTVF250NC5‐PE
2025
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 + P‐VTVF250PC5‐PE
2025
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 |