Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(4)
AUX
(10)
BOSCH
(6)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(152)
EQUATION
(0)
FUJI ELECTRIC
(20)
FUJITSU
(63)
Fujitsu Atlantic
(22)
GENERAL
(15)
GREE
(1)
GSS
(0)
HAIER
(86)
HEC
(0)
HEIWA
(0)
HISENSE
(22)
HITACHI
(21)
IVT
(2)
Inventor
(23)
KAYSUN
(4)
LG
(28)
MIDEA
(39)
MITSUBISHI ELECTRIC
(97)
Mitsubishi Heavy Industries
(131)
NORD
(3)
Nobu
(0)
PANASONIC
(29)
RIELLO
(9)
Rotenso
(0)
SAMSUNG
(18)
THERMOR
(3)
TOSHIBA
(53)
Viessmann
(6)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC71VNP-W/FDF71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.91 | 3.51 | -15° | 7.10 | 5.70 | |
|
FDC71VNP-W/FDF71VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.91 | 3.51 | -15° | 7.10 | 5.70 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
AC140S2SK1FA/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
RXM60R / FHA60A9
RXM
|
DAIKIN | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 3.87 | 3.32 | -15° | 5.70 | 4.71 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOX630U-48HFN8-RRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.45 | -10° | 14.10 | 11.40 | |
|
MOX630U-48HFN8-R(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.45 | -10° | 14.10 | 11.40 | |
|
MOX630U-48HFN8-R(GA)/MFM-48HRFN8-QRD0W V1
Floor Standing R32
|
MIDEA | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.45 | -10° | 14.10 | 11.40 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
MOX630U-55HFN8-RRD0W(GA)/MFM-55HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MO-55N8-R-1/MFM-55N8
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-R(GA)/MFM-55HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-R OUT V1/MFM-55HRFN8-Q IN V1
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
KUE-160 DTR14/KPV-160 DR14
Zen
|
KAYSUN | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-RRD0W(GA)-GR/MFM-55HRFN8-QRD0W-GR
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABEG24KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
42QZL060D8S/38QUS060D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
AF42S2SD1FA/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF42S2SD1FA(H)/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF42S2SD1FA(D)/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
NAGANO CONSOLE IC42V3-NG / E1U42L-NG
NAGANO CONSOLE
|
THERMOR | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
42QZL048D8S/38QUS048D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
AC105S2SH2FA(H)/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.91 | 3.50 | -10° | 9.50 | 6.00 | |
|
SUZ-M25VA/MFZ-KT25VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 2.50 | 2.20 | |
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
FUJITSU | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOHG45LATT/ABHG45LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
FDC140VSX-W/FDF140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.72 | 3.41 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDF140VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.72 | 3.41 | 14.00 | 15.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.05 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.05 | 13.40 | 8.50 | ||
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
RZASG100MV1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | 4.92 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FUA100A
RZASG
|
DAIKIN | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 4.01 | -10° | 9.50 | 6.00 | ||
|
AB140S2SR1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 4.00 | 2.63 | 13.40 | 8.50 |