Filters · 3 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(43)
ATLANTIC
(34)
AUX
(117)
BOSCH
(99)
BRYANT
(6)
Buderus
(35)
CARRIER
(105)
CIAT
(14)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(344)
DE DIETRICH
(18)
EQUATION
(5)
FUJI ELECTRIC
(72)
FUJITSU
(149)
Fujitsu Atlantic
(82)
GENERAL
(133)
GREE
(120)
GSS
(4)
HAIER
(352)
HEC
(5)
HEIWA
(8)
HISENSE
(337)
HITACHI
(69)
IVT
(8)
Inventor
(95)
KAYSUN
(17)
LG
(213)
MIDEA
(545)
MITSUBISHI ELECTRIC
(227)
Mitsubishi Heavy Industries
(104)
NORD
(31)
Nobu
(8)
PANASONIC
(209)
PITSOS
(6)
RIELLO
(16)
Rotenso
(0)
SAMSUNG
(129)
THERMOR
(46)
TOSHIBA
(170)
Viessmann
(4)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(15)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEH07KLTA/ASEH07KLTBL
ASE**K
|
FUJITSU | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AJ052TXJ3KG / AR70F09C1AW / AR70F09C1AW
FJM
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.03 | 3.63 | -10° | 5.00 | 4.91 | |
|
SRC50ZTL-W/SRK50ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.58 | -10° | 5.00 | 4.00 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOHG24KBTA3/ASHG12KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
ROG24KBTA3/RSG12KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOEG24KBCA3/ASEH12KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AS71S2SF1FA-BH/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.26 | -10° | 7.00 | 5.60 | |
|
AS71S2SF1FA-WH/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.26 | -10° | 7.00 | 5.60 | |
|
A09GA1 U18 / A09GA1 NSE
U18A
|
LG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
A09GA2 U18 / A09GA2 NSE
U18A
|
LG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
A09GA2U EEU / A09GA2N EEU
U18A
|
LG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 | |
|
RAS-13J2AVSG-E1/RAS-B13J2FVG-E
Console
|
TOSHIBA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 4.54 | 3.31 | -15° | 3.50 | 3.00 | |
|
AS42XCAHRA-1/1U42S2SM1FA
Supermatch Expert White
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 4.20 | 3.60 | |
|
AS42XCAHRA-MB1/1U42S2SM1FA
Supermatch Expert Black
|
HAIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 4.20 | 3.60 | |
|
MOX130-07HFN8-QRD1GW/MSAGAU-07HRFN8-QRD1GW
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 2.10 | 1.80 | |
|
42QHG007D8SH/38QHG007D8SH
Wall mounted
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 2.10 | 1.80 | |
|
U-125PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
U-125PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
RAS-5M34G3AVG-E1/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
38WH5M100C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
RAS-5M34G3AVG-E1/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
CU-TZ71CKEW / CS-TZ71CKEW
2025
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
MUZ-DW50VF/MSZ-DW50VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF/MSZ-HR50VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF2/MSZ-HR50VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MOX130-12HFN8-QRD2GW/MSGPBU-12HRFN8-QRD2GW
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
MX1-12RD1H/EF-12RD1H
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
MX1H-12RD1H/EF-12RD1H
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
NRO-12/NRI-12WFI
Nura
|
Inventor | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
DURA-12RD1-OUT/DURA-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
LINE-12RD1-OUT/LINE-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
PRO-12RD1-OUT/PRO-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
42QCE012D8SM*/38QCE012D8SM
Wall mounted
|
CARRIER | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
GWH09AGC-K6DNA1F
MONOSPLITS
|
GREE | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | -10° | 2.70 | 2.70 | ||
|
GWH09ACCXB-K6DNA1Y
MONOSPLITS
|
GREE | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 4.28 | -10° | 2.70 | 2.70 | |
|
RXC60D / FTXC60D
RXC
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.24 | 3.81 | -14° | 6.21 | 4.10 | |
|
U-100PZ3E5 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
U-100PZ3E8 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
RZAG71NV1 / FAA71B
RZAG
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.20 | 3.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FAA71B
RZAG
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.20 | 3.42 | -10° | 6.80 | 4.70 | |
|
RAV-GM901ATP-E/RAV-HM901KRTP-E
DI
|
TOSHIBA | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.10 | -15° | 8.00 | 6.30 | |
|
CU-UZ25CKE / CS-UZ25CKE
2025
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.06 | -15° | 2.50 | 2.10 | |
|
RAV-GM402ATP-E/RAV-HM401KRTP-E
DI
|
TOSHIBA | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.24 | 3.57 | -15° | 3.60 | 2.70 | |
|
U-100PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
RAV-GM802ATW-E/RAV-HM801KRTP-E
DI
|
TOSHIBA | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.05 | 3.35 | -15° | 6.70 | 5.10 |