Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(52)
ATLANTIC
(34)
AUX
(121)
BOSCH
(105)
BRYANT
(6)
Buderus
(36)
CARRIER
(107)
CIAT
(16)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(344)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(72)
FUJITSU
(149)
Fujitsu Atlantic
(82)
GENERAL
(133)
GREE
(120)
GSS
(4)
HAIER
(357)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(72)
IVT
(10)
Inventor
(98)
KAYSUN
(20)
LG
(216)
MIDEA
(568)
MITSUBISHI ELECTRIC
(227)
Mitsubishi Heavy Industries
(104)
NORD
(34)
Nobu
(8)
PANASONIC
(217)
PITSOS
(6)
RIELLO
(18)
Rotenso
(0)
SAMSUNG
(129)
THERMOR
(49)
TOSHIBA
(170)
Viessmann
(6)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(15)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOM-18N8D0-1/MAG2-18N8-2
Extreme save R32
|
MIDEA | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -10° | 5.30 | 4.20 | |
|
MUSE-40-2 (7722650) / UMS 20 (7802984) / UMS 20 (7802984)
CLIM'UP MULTISPLIT
|
DE DIETRICH | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
AR5VO-12/AR5VI-12WFI
Aria (AR5)
|
Inventor | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 3.50 | 2.91 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
MUSE 40-2 (7722650) / UMS 2 20 (7910476) x 2
CLIM'UP MULTI
|
DE DIETRICH | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
RAV-GM801ATP-E/RAV-HM801KRTP-E
DI
|
TOSHIBA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.73 | 4.01 | 2.95 | -15° | 6.70 | 5.10 | |
|
MUZ-HR35VF/MSZ-HR35VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-DW35VF/MSZ-DW35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-HR35VF2/MSZ-HR35VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -10° | 3.40 | 2.40 | |
|
HDLE-050N-09M25/YDAE-050R-09M25
Aura V2
|
AIRWELL | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.90 | -10° | 4.60 | 3.70 | |
|
GWH18AZDXB-K6DNA3Z
MONOSPLITS
|
GREE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.75 | -10° | 4.60 | 3.70 | |
|
GWH18AWDXB-K6DNA4Z
MONOSPLITS
|
GREE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.75 | -10° | 4.60 | 3.70 | |
|
AC20LC0EW/HC20LC00G
Max Comfort
|
HISENSE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
AC20LC00W/HC20LC00G
Max Comfort
|
HISENSE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
AC20LC00W/HC20LC0UG
Max Comfort
|
HISENSE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
AC20LC0FW/HC20LC00G
Max Comfort
|
HISENSE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
AC20LC0AW/HC20LC00G
Max Comfort
|
HISENSE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
AC20LC0AW/HC20LC0UG
Max Comfort
|
HISENSE | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
RAS-13B2AVG-E2/RAS-B13B2KVG-E3
SEIYA
|
TOSHIBA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
38WHSS035ATA0TEE/40WHSW035DTA0TEE
40WHS
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
AS35PBUHRA/1U35YEUFRA
Pearl Neo
|
HAIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
AS35PBUHRA-MT/1U35YEUFRA-MT
Pearl Plus
|
HAIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
AS35QAIN/US35QAOD
NORD - P plus
|
NORD | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.17 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
RXQ25A / FTXQ25A
RXQ
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 4.22 | 3.71 | -10° | 2.50 | 2.30 | |
|
PUZ-M100YKA2/PKA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PKA-M100KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PKA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA2/PKA-M100KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PKA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PKA-M100KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PKA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PKA-M100KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.41 | -15° | 9.50 | 8.00 | |
|
AS25PBUHRA/1U25YETFRA
Pearl Neo
|
HAIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25PBUHRA-MT/1U25YETFRA-MT
Pearl Plus
|
HAIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25QAIN/US25QAOD
NORD - P plus
|
NORD | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.70 | 2.60 | |
|
AM4-H28/4DR3D+AMWM-H09/4R3HA(M*)+AMWM-H18/4R3HA(M*)
M SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
AM4-H28/4DR3D+AMWM-H09/4R3HA(C*)+AMWM-H18/4R3HA(C*)
C SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM82M(4)-T1B+FTXM26CU1-A+FTXM52CU1-A
CU PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM82M(4)-T1B+FTXM26CA-A+FTXM52CA-A
CA PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM80M(4)-T1A+FTXM26CU1-A+FTXM52CU1-A
CU PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
RXYM80M(4)-T1A+FTXM26CA-A+FTXM52CA-A
CA PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.71 | -10° | 8.20 | 6.50 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
MOX133-09HFN8-QRD1GW/MSAGAU-09HRFN8-QRD1GW
Extreme save R32
|
MIDEA | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 |