Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(64)
ATLANTIC
(38)
AUX
(129)
BOSCH
(116)
BRYANT
(6)
Buderus
(36)
CARRIER
(126)
CIAT
(27)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(500)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(105)
FUJITSU
(217)
Fujitsu Atlantic
(117)
GENERAL
(168)
GREE
(126)
GSS
(4)
HAIER
(420)
HEC
(5)
HEIWA
(8)
HISENSE
(366)
HITACHI
(100)
IVT
(10)
Inventor
(114)
KAYSUN
(37)
LG
(268)
MIDEA
(664)
MITSUBISHI ELECTRIC
(360)
Mitsubishi Heavy Industries
(188)
NORD
(40)
Nobu
(8)
PANASONIC
(249)
PITSOS
(6)
RIELLO
(29)
Rotenso
(3)
SAMSUNG
(167)
THERMOR
(53)
TOSHIBA
(217)
Viessmann
(13)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(24)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PC24SC U24T / PC24SC NSKT
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AC24BK NSKC/AC24BK U24C
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24ST NSKC/PC24ST U24C
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
DC24RH U24 / DC24RH NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24ETK NSKS / S24ETK U24S
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 5.00 | |
|
M4OA-27HFN8-Q(HRU)/MSAGAU-09HRFN8-QRD1GW+MSAGCU-18HRFNX-QRD0GW
M4OA-27HFN8-Q(HRU)
|
MIDEA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 7.90 | 6.20 | |
|
AUW40U4RS7/AKT40UR4RK8
Super Inverter R32
|
HISENSE | Console | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.54 | -10° | 4.10 | 3.50 | |
|
RAV-GV561ATP-E/RAV-HM561UTP-E
DIC
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.79 | -15° | 5.00 | 2.80 | |
|
RAV-GM1101ATP-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
CU-RZ25WKE / CS-RZ25WKEW
2019
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
CU-RZ25ZKE / CS-RZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
FDC71VNP-W/SRK71ZR-W
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 4.55 | 3.78 | -15° | 7.10 | 5.70 | |
|
PUZ-ZM60VHA2/PKA-M60KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PKA-M60KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PKA-M60KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.04 | -20° | 6.10 | 4.40 | |
|
Z4UW30GFA3 / ZMNW07GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.01 | 3.50 | -10° | 7.70 | 5.90 | |
|
ASW-H24G3B4/CBR3DI-B9 / ASW-H24G3B4/CBR3DI-B9
C SERIES
|
AUX | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.04 | -10° | 6.70 | 5.30 | |
|
ASW-H24G3B4/CAR3DI-B9 / ASW-H24G3B4/CAR3DI-B9
C SERIES
|
AUX | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.04 | -10° | 6.70 | 5.30 | |
|
CU-4Z80CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.33 | -15° | 8.00 | 6.80 | |
|
3AMW62U4RJC/HA25XU00G/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 3.58 | -10° | 5.80 | 5.00 | |
|
3AMW62U4RJC/HB25XU0AG/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 3.58 | -10° | 5.80 | 5.00 | |
|
3AMW62U4RJC/HB25XU0BG/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 3.58 | -10° | 5.80 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOHG18KBTA3/ASHG07KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
MXZ-5F102VF2/MSZ-AY42VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
MXZ-5F102VF3/MSZ-AY42VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
CL5000i 35 E / CL5000iU W 35 E
Climate 5000i
|
BOSCH | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.30 | 3.93 | -10° | 3.30 | 2.60 | |
|
5MXM90A9 / FTXM20R / FTXM71R
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.26 | 3.69 | -15° | 8.00 | 4.50 | |
|
5MXM90A9 / FTXM20A / FTXM71A
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.26 | 3.69 | -15° | 8.00 | 4.50 | |
|
AUW35U4RS8/AKT35UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.78 | -10° | 3.50 | 3.00 | |
|
5MXM90A9 / CTXM15R / FTXM71R
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.28 | 3.67 | -15° | 8.00 | 4.50 | |
|
5MXM90A9 / CTXM15A / FTXM71A
5MXM
|
DAIKIN | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.28 | 3.67 | -15° | 8.00 | 4.50 | |
|
AOHG24KLTA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOHG24KLCA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOEG24KLCA/ASEG24KLCA
ASE**K
|
FUJITSU | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
RAV-GM1101ATP-E/RAV-HM1101KRTP-E
DI
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.23 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101KRTP-E
DI 3ph
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.23 | -15° | 9.50 | 8.00 |