Filters · 4 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(55)
ATLANTIC
(38)
AUX
(127)
BOSCH
(105)
BRYANT
(6)
Buderus
(36)
CARRIER
(117)
CIAT
(22)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(456)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(89)
FUJITSU
(203)
Fujitsu Atlantic
(101)
GENERAL
(145)
GREE
(120)
GSS
(4)
HAIER
(408)
HEC
(5)
HEIWA
(8)
HISENSE
(348)
HITACHI
(83)
IVT
(10)
Inventor
(106)
KAYSUN
(20)
LG
(238)
MIDEA
(568)
MITSUBISHI ELECTRIC
(270)
Mitsubishi Heavy Industries
(168)
NORD
(34)
Nobu
(8)
PANASONIC
(238)
PITSOS
(6)
RIELLO
(24)
Rotenso
(0)
SAMSUNG
(140)
THERMOR
(49)
TOSHIBA
(199)
Viessmann
(10)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(19)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ARXQ35A / ATXQ35A
ARXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.11 | 3.71 | -10° | 3.50 | 2.40 | |
|
AS50XCAHRA/1U50S2SJ2FA-2
EXPERT
|
HAIER | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 4.00 | -10° | 5.00 | 4.60 | |
|
AS50XCAHRA-MB/1U50S2SJ2FA-2
EXPERT
|
HAIER | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 4.00 | -10° | 5.00 | 4.60 | |
|
RAS-05B2AVG-E2/RAS-B05B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.26 | -15° | 1.50 | 1.60 | |
|
RAS-05B2AVG-E2/RAS-B05B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.26 | -15° | 1.50 | 1.60 | |
|
RAS-4HRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
38QUS014D8S2-1/42QHE07D8SH*
Wall mounted
|
CARRIER | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 4.00 | 4.65 | -10° | 4.10 | 3.80 | |
|
MXZ-3F68VF4/MSZ-AY20VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 3.81 | 3.16 | -15° | 6.20 | 6.80 | |
|
MXZ-3F68VF5/MSZ-AY20VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 3.81 | 3.16 | -15° | 6.20 | 6.80 | |
|
CU-PZ35WKE / CS-PZ35WKE
2019
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.69 | -15° | 3.40 | 2.40 | |
|
ARXQ25A / ATXQ25A
ARXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.15 | 3.71 | -10° | 2.50 | 2.30 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(H*)X2
Halo
|
AUX | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.03 | 3.72 | -10° | 5.40 | 4.40 | |
|
RZASG71MV1 / FUA71A
RZASG
|
DAIKIN | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 3.90 | 3.89 | -10° | 6.80 | 4.50 | |
|
5MWXM68A9 / FTXM50A / CTXM15A
5MWXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.85 | 3.85 | 3.35 | -15° | 6.50 | 4.50 | |
|
AOHG07KPCA/ASHG07KPCA
ASH**L
|
GENERAL | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG07KPCA/ASHG07KPCE
ASH**L
|
GENERAL | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
ROG07KPCA/RSG07KPCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
FUJITSU | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOEG07KPCA/ASEG07KPCE
ASE**K
|
FUJITSU | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG09KPCA/ASHG09KPCA
ASH**L
|
GENERAL | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOHG09KPCA/ASHG09KPCE
ASH**L
|
GENERAL | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
ROG09KPCA/RSG09KPCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG09KPCA/ASYG09KPCE
ASY**K
|
FUJITSU | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG025KPCA/ASYG025KPCA
ASY**K
|
FUJITSU | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOEG09KPCA/ASEG09KPCE
ASE**K
|
FUJITSU | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG09KPCA/ASYG09KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG025KPCA/ASYG025KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
U-140PZH4E5 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
5MWXM90A9 / FTXM50A / FTXM42A
5MWXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.98 | 3.23 | -15° | 8.00 | 5.20 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(Q*)X2
Q-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.04 | 2.81 | -10° | 5.40 | 4.40 | |
|
2MXM68A9 / FTXM50R / CTXM15R
2MXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
3MXM68A9 / CTXM15R / FTXM50R
3MXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
4MXM68A9 / CTXM15R / FTXM50R
4MXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
2MXM68A9 / FTXM50A / CTXM15A
2MXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
3MXM68A9 / CTXM15A / FTXM50A
3MXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
4MXM68A9 / CTXM15A / FTXM50A
4MXM
|
DAIKIN | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.83 | 3.87 | 3.86 | -15° | 6.50 | 4.50 | |
|
RAC-CJ25WHAE / RAK-CJ25PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -15° | 2.40 | 2.47 | |
|
MUSE-50-2 (7802989) / UMS 25 (7802985) / UMS 25 (7802985)
CLIM'UP MULTISPLIT
|
DE DIETRICH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
AS42S2SF1FA-MB3/1U42S2SM1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
AS42S2SF1FA-MW3/1U42S2SM1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO UI MURALE 4200W R32 / NAGANO U.E MONO 4200W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V2-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V2-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V3-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V3-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
AS68RDAHRA-3/1U68MRAFRA-3
Revive Plus
|
HAIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 6.20 | 4.60 | |
|
PFZUVO-24/PFZUVI-24WIFI
Professional Z
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.61 | -10° | 6.20 | 4.60 |