Filters · 2 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(52)
ATLANTIC
(34)
AUX
(46)
BOSCH
(95)
BRYANT
(6)
Buderus
(36)
CARRIER
(97)
CIAT
(16)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(344)
EQUATION
(5)
FUJI ELECTRIC
(72)
FUJITSU
(149)
Fujitsu Atlantic
(82)
GENERAL
(133)
GREE
(103)
GSS
(4)
HAIER
(347)
HEC
(5)
HEIWA
(8)
HISENSE
(270)
HITACHI
(69)
IVT
(10)
Inventor
(98)
KAYSUN
(16)
LG
(210)
MIDEA
(567)
MITSUBISHI ELECTRIC
(227)
Mitsubishi Heavy Industries
(104)
NORD
(34)
Nobu
(8)
PANASONIC
(217)
RIELLO
(18)
Rotenso
(0)
SAMSUNG
(129)
THERMOR
(49)
TOSHIBA
(170)
Viessmann
(6)
Vulcano
(16)
WESTPOINT
(22)
YORK
(15)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-2TZ50TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.35 | -15° | 5.00 | 4.50 | |
|
MU5R36 U36A0 / MJ18PC NSK0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.15 | 3.25 | -10° | 9.20 | 6.80 | |
|
AOHG24KLTA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOHG24KLCA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOEG24KLCA/ASEG24KLCA
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AS25PBPHRA-PRE/1U25YEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
AS25PBPHRA-PRE/1U25YEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
UI 2,7 kW MURAO SMART BLANC & UE MONO 2,7 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
GWH12ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.20 | -10° | 3.20 | 2.80 | |
|
CU-RZ25CKE / CS-RZ25CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
RM3U19 U24 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.26 | 4.22 | -10° | 5.27 | 4.50 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
MXZ-5F102VF2/MSZ-AY42VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
MXZ-5F102VF3/MSZ-AY42VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
AS35XV2EW/QH35XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2EW/QH35XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2FW/QH35XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2FW/QH35XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AF35S2SD1FA/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(D)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
MUZ-SF25VE/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.40 | 4.10 | -15° | 2.50 | 2.40 | |
|
MUZ-GF60VE/MSZ-GF60VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.76 | -15° | 6.10 | 4.60 | |
|
GWHD(28)NK6OO GWH09AGCXB-K6DNA1G/I+GWH18AGD-K6DNA1E/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.53 | -10° | 8.00 | 6.60 | |
|
CU-Z42ZKE / CS-Z42ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42ZKE / CS-XZ42ZKEW-H
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42CKE / CS-Z42CKEW-H
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42CKE / CS-XZ42CKEW-H
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
AUW26U4RS8/AKT26UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 2.60 | 3.00 | |
|
MXZ-2D53VAH2/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.76 | -20° | 5.30 | 4.50 | |
|
GWH18ACDXF-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.00 | -10° | 5.30 | 4.30 | |
|
CU-TZ60CKE / CS-TZ60CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.72 | -15° | 6.00 | 4.40 | |
|
RAV-GM902ATW-E/RAV-HM901KRTP-E
DI
|
TOSHIBA | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.30 | -15° | 8.00 | 6.30 | |
|
MUZ-BT35VG/MSZ-BT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.40 | |
|
AS25XCHHRA-NR/1U25KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 4.20 | -10° | 2.60 | 3.00 | |
|
CU-RZ50WKE / CS-RZ50WKEW
2019
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50ZKE / CS-RZ50ZKEW
2023
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50CKE / CS-RZ50CKEW
2025
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
P12SND NS0/P12SND U12A
U12A
|
LG | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.60 | 4.11 | -10° | 3.50 | 2.70 | |
|
AOEH14KACB2/ASEH07KLTBL/ASEH07KLTBL
AOE**K Multi
|
FUJITSU | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.30 | 4.33 | -15° | 4.00 | 3.30 | |
|
AOHH14KACB2/ASHH07KLTBL/ASHH07KLTBL
AOH**K Multi
|
GENERAL | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.30 | 4.33 | -15° | 4.00 | 3.30 | |
|
MXZ-2HA50VF2/MSZ-HR25VF/MSZ-HR25VF
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.78 | 4.30 | 3.90 | -15° | 5.00 | 3.20 |