Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(43)
ATLANTIC
(34)
AUX
(42)
BOSCH
(89)
BRYANT
(6)
Buderus
(35)
CARRIER
(95)
CIAT
(14)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(344)
EQUATION
(5)
FUJI ELECTRIC
(72)
FUJITSU
(149)
Fujitsu Atlantic
(82)
GENERAL
(133)
GREE
(103)
GSS
(4)
HAIER
(336)
HEC
(5)
HEIWA
(8)
HISENSE
(264)
HITACHI
(69)
IVT
(8)
Inventor
(95)
KAYSUN
(13)
LG
(207)
MIDEA
(544)
MITSUBISHI ELECTRIC
(227)
Mitsubishi Heavy Industries
(104)
NORD
(31)
Nobu
(8)
PANASONIC
(209)
RIELLO
(16)
Rotenso
(0)
SAMSUNG
(129)
THERMOR
(46)
TOSHIBA
(170)
Viessmann
(4)
Vulcano
(16)
WESTPOINT
(22)
YORK
(15)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG14KGCA/ASYG14KGTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
RZAG50B / FTXM50A
RZAG
|
DAIKIN | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.60 | 4.00 | -10° | 5.00 | 4.50 | |
|
GWH18AUDXE-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.10 | -10° | 5.30 | 4.10 | |
|
42QHG009D8SH*/38QHG009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
42HG09JS8C-1/38HG09JS8C-1
Wall mounted
|
CIAT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
WR225HJM8-1/AIR225HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
COLI09D8SHF/COLI09D8SHC
Wall mounted
|
COLIBRI | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
MOX230-09HFN8/MSAGBU-09HRFN8/GR
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
AG1-09NXD6-O/AG1-09NXD6-I
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
AG1-09NXD6-O(R)/AG1-09NXD6-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
MOX230-09HFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)-HIWF
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
AG1-09NXD6-O(B)/AG1-09NXD6-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
X2-09N8D6-O/AGU-09NXD1-I
Extreme save R32
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
WIMO-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
FDC100VNA-W/SRK100ZR-W
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.22 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 | |
|
FDC100VNA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
AOEH30KMTB/ASEH30KMTB
ASE**K
|
FUJITSU | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOHH30KMTB/ASHH30KMTB
ASY**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOYH30KMTB/ASYH30KMTB
ASY**K
|
FUJITSU | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
ROH30KMTB/RSH30KMTB
RS**K
|
FUJI ELECTRIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOYH30KMTB/ASYH30KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AS25XCAHRA+AS25XCAHRA/2U40S2SM1FA
Super Match Multi-Tundra
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
AS25XCAHRA-MB+AS25XCAHRA-MB/2U40S2SM1FA
Super Match Multi-Expert
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
SCM30ZS-W/SRK15ZS-WF/SRK15ZS-WF
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.07 | 4.80 | 5.41 | -10° | 3.00 | 3.30 | |
|
RXA50B / FTXA50AW
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BS
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BT
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BB
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEG24KMTA/ASEG24KMTE
ASE**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
GWH09AVCXB-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
AS50KBAHRA-MW/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
AS50KBAHRA-MB/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
AS50KBAHRA-W/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
U-60PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.27 | -15° | 6.10 | 4.60 | |
|
GWH24AUDXF-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
GWH24AUDXF-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
HMIP2-70W-EUV1 / HMEP2-70-EUV1
HYOKO2
|
HEIWA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
MUZ-EF35VGH/MSZ-EF35VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.50 | 4.21 | -20° | 3.50 | 2.90 | |
|
MUZ-EF35VGH2/MSZ-EF35VGK2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.50 | 4.21 | -20° | 3.50 | 2.90 | |
|
MOX230-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
GFCAGBU-12HRFN8-PRO/GFCAGBU-12HRFN8-PRO
Extreme save R32
|
CONFORT AIR | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
X2AGN-12N8D6-OH/AGN-12N8D1-IH
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
MOX201-12HFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Xtreme Heat R32
|
MIDEA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 |