Filters · 2 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(15)
ATLANTIC
(15)
AUX
(4)
BOSCH
(58)
BRYANT
(0)
Buderus
(18)
CARRIER
(48)
CIAT
(2)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(182)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(60)
Fujitsu Atlantic
(28)
GENERAL
(64)
GREE
(27)
GSS
(0)
HAIER
(128)
HEC
(0)
HEIWA
(3)
HISENSE
(114)
HITACHI
(43)
IVT
(7)
Inventor
(35)
KAYSUN
(4)
LG
(30)
MIDEA
(189)
MITSUBISHI ELECTRIC
(72)
Mitsubishi Heavy Industries
(58)
NORD
(13)
Nobu
(0)
PANASONIC
(88)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(47)
THERMOR
(15)
TOSHIBA
(93)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(13)
YORK
(2)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-RZ35WKE / CS-RZ35WKEW
2019
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
RAS-07E2AVG-E/RAS-B07E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-07E2AVG-E/RAS-B07S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
CU-RZ35ZKE / CS-RZ35ZKEW
2023
|
PANASONIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
CU-RZ25WKE / CS-RZ25WKEW
2019
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
CU-RZ25ZKE / CS-RZ25ZKEW
2023
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
SRC35ZTL-W/SRK35ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.70 | 4.22 | -10° | 3.50 | 2.80 | |
|
CU-RZ35CKE / CS-RZ35CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
CU-TZ35WKE / CS-TZ35WKEW
2019
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 4.04 | -15° | 3.50 | 2.80 | |
|
CU-TZ35ZKE / CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 4.04 | -15° | 3.50 | 2.80 | |
|
MUZ-BT35VG2/MSZ-BT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.50 | |
|
GWH12ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.20 | -10° | 3.20 | 2.80 | |
|
CU-RZ25CKE / CS-RZ25CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AS35XV2EW/QH35XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2EW/QH35XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2FW/QH35XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2FW/QH35XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
MUZ-BT35VG/MSZ-BT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.40 | |
|
P12SND NS0/P12SND U12A
U12A
|
LG | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.60 | 4.11 | -10° | 3.50 | 2.70 | |
|
DC12RK UL2 / DC12RK NSJ
UL2
|
LG | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.60 | 4.10 | -10° | 3.50 | 2.90 | |
|
ARXP25N / ATXP25N
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
ARXP25N9 / ATXP25N9
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
RAS-13CAVG-E/RAS-B13CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.91 | -15° | 3.30 | 2.70 | |
|
RAS-13E2AVG-E/RAS-B13E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.91 | -15° | 3.30 | 2.70 | |
|
RAS-13E2AVG-E/RAS-B13S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.14 | -15° | 3.30 | 2.70 | |
|
38WHSM035A1A0TEE/40WHMW035D1A0TEE
40WHM
|
CARRIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.14 | -15° | 3.30 | 2.70 | |
|
SRC25ZTL-W/SRK25ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.70 | 4.55 | -10° | 2.50 | 2.70 | |
|
AS25XV2EW/QH25XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.60 | 4.15 | -10° | 2.60 | 2.90 | |
|
AS25XV2EW/QH25XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.60 | 4.15 | -10° | 2.60 | 2.90 | |
|
AS25XV2FW/QH25XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.60 | 4.15 | -10° | 2.60 | 2.90 | |
|
AS25XV2FW/QH25XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.60 | 4.15 | -10° | 2.60 | 2.90 | |
|
DC09RK UL2 / DC09RK NSJ
UL2
|
LG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.50 | -10° | 2.50 | 2.80 | |
|
CU-TZ20WKE / CS-TZ20WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.15 | -15° | 2.00 | 1.90 | |
|
RZAG35B / FTXM35A
RZAG
|
DAIKIN | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 3.85 | -10° | 3.50 | 2.60 | |
|
P09SND NS0/P09SND U12A
U12A
|
LG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 4.32 | -10° | 2.50 | 2.70 | |
|
CU-TZ25WKE / CS-TZ25WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
RAS-10CAVG-E/RAS-B10CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
MOX230-09AFN8-QRD6GW/MSAGBU-09HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
MOX230-12AFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
YHKF12XEEDMH-RY / YHKF12YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 3.80 | -10° | 3.50 | 2.60 |