Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(76)
ATLANTIC
(36)
AUX
(103)
BOSCH
(115)
BRYANT
(6)
Buderus
(26)
CARRIER
(111)
CIAT
(30)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(14)
DAIKIN
(509)
DE DIETRICH
(16)
EQUATION
(4)
FUJI ELECTRIC
(162)
FUJITSU
(390)
Fujitsu Atlantic
(200)
GENERAL
(236)
GREE
(130)
GSS
(4)
HAIER
(306)
HEC
(3)
HEIWA
(8)
HISENSE
(379)
HITACHI
(133)
IVT
(10)
Inventor
(140)
KAYSUN
(74)
LG
(2)
MIDEA
(773)
MITSUBISHI ELECTRIC
(505)
Mitsubishi Heavy Industries
(267)
NORD
(41)
Nobu
(8)
PANASONIC
(256)
PITSOS
(6)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(192)
THERMOR
(41)
TOSHIBA
(262)
Viessmann
(24)
Vulcano
(8)
WESTPOINT
(23)
XTRON
(4)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOD30-24AFN8-QRD1GW/MSEPDU-24HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
Aero 607-1 O / Aero 607-1 I
Aero 600-1
|
IVT | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
RZAG100NV1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | 4.03 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | -10° | 9.50 | 7.80 | ||
|
RZAG100NV1 / FBA100A
RZAG
|
DAIKIN | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.36 | -10° | 9.50 | 7.80 | ||
|
RZAG100NY1 / FBA100A
RZAG
|
DAIKIN | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.36 | -10° | 9.50 | 7.80 | ||
|
AUD125UX4REH8/AUW125U6RN8
Turbo Inverter R32
|
HISENSE | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.27 | 3.71 | -10° | 12.10 | 9.00 | |
|
RAS-05E2AVG-E/RAS-B05E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.60 | 4.26 | -15° | 1.50 | 1.60 | |
|
RAS-05E2AVG-E/RAS-B05S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.60 | 4.26 | -15° | 1.50 | 1.60 | |
|
PUZ-ZM35VKA3/PLA-M35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.70 | |
|
RAV-GP1401AT8-E1/RAV-HM1401CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.21 | 4.02 | -20° | 12.50 | 11.80 | |
|
AR12TXCACWKN/AR12TXCACWKX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AR12BXFYDWKN/AR12BXFYDWKX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
GWH18AUDXF-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -10° | 5.30 | 4.20 | |
|
GWH18AVDXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.10 | -10° | 5.30 | 4.20 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
U-140PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.64 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
AS25KBAHRA-MB/1U25MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-MW/1U25MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-W/1U25MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS35KBAHRA-MB/1U35MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
AS35KBAHRA-MW/1U35MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
AS35KBAHRA-W/1U35MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
SRC50ZT-W/SRC50ZT-WF
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.92 | -10° | 5.00 | 4.80 | |
|
SRC50ZT-W/SRC50ZT-WFB
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.92 | -10° | 5.00 | 4.80 | |
|
SRC50ZT-W/SRC50ZT-WFT
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.92 | -10° | 5.00 | 4.80 | |
|
U-140PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
PUZ-ZM140YDA/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.31 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.31 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
ARXM50A / ATXM50A
ARXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.65 | 4.75 | 4.05 | -10° | 5.00 | 4.50 | |
|
ARXM50A9 / ATXM50A
ARXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.65 | 4.75 | 4.05 | -10° | 5.00 | 4.50 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
RAV-GM402ATP-E/RAV-HM401MUTP-E
DI
|
TOSHIBA | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.46 | 4.21 | -15° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA3/PEAD-M35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.20 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PEAD-M35JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.20 | -11° | 3.60 | 2.40 | |
|
RAC-VJ18WHAE / RAK-VJ18RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.82 | -15° | 2.00 | 2.30 | |
|
SRC71ZR-W/SRK71ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -15° | 7.10 | 6.60 | |
|
AOYG18KMTA/ASYG18KMTE
ASY**K
|
FUJITSU | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOHG18KMTA/ASHG18KMTE
ASH**K
|
GENERAL | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
ROG18KMTA/RSG18KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOEG18KMTA/ASEG18KMTE
ASE**K
|
FUJITSU | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOYG18KMTA/ASYG18KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
RZAG100NV1 / FCAG100B
RZAG
|
DAIKIN | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.53 | 3.59 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FCAG100B
RZAG
|
DAIKIN | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.53 | -10° | 9.50 | 7.80 | ||
|
RAV-GP1401AT8-E1/RAV-HM1401UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.37 | 4.11 | -20° | 12.50 | 9.50 | |
|
PUZ-ZM100VDA/PCA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PCA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
CU-Z25YKEA / CS-Z25YKEA
2022
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 |