Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(38)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(130)
CIAT
(36)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(522)
EQUATION
(5)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(122)
GSS
(4)
HAIER
(445)
HEC
(5)
HEIWA
(8)
HISENSE
(314)
HITACHI
(147)
IVT
(10)
Inventor
(124)
KAYSUN
(47)
LG
(291)
MIDEA
(728)
MITSUBISHI ELECTRIC
(446)
Mitsubishi Heavy Industries
(201)
NORD
(52)
Nobu
(8)
PANASONIC
(253)
RIELLO
(38)
Rotenso
(0)
SAMSUNG
(187)
THERMOR
(58)
TOSHIBA
(238)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(31)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AB50S2SA1FA/1U50S2SJ2FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 5.00 | 4.00 | |
|
AB50S2SA1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 5.00 | 4.00 | |
|
CU-UZ25WKE / CS-UZ25WKE
2019
|
PANASONIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 4.05 | -15° | 2.50 | 1.90 | |
|
2MXM68A9 / FTXM42R / FTXM25R
2MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
3MXM68A9 / FTXM25R / FTXM42R
3MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
4MXM68A9 / FTXM25R / FTXM42R
4MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
2MXM68A9 / FTXM42A / FTXM25A
2MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
3MXM68A9 / FTXM25A / FTXM42A
3MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
4MXM68A9 / FTXM25A / FTXM42A
4MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
SRC25ZSP-W1/SRK25ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 4.05 | -10° | 2.50 | 2.70 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
ROG14KATA/RCG14KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/AUXG14KVLA
AUXG**K
|
GENERAL | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
3N60WEAFRA-W/AS25SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 5.20 | 4.60 | |
|
AM2-H18/4DR3C+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -10° | 5.30 | 4.50 | |
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
NAGANO GAINABLE MP IG95MP-NG / E1U90LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.49 | -10° | 9.50 | 7.20 | |
|
M3OA-18HFN8-Q/MSCB1BU-09HRFN8-QRD1GW+MSCB1BU-09HRFN8-QRD1GW
M3OA-18HFN8-Q
|
MIDEA | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.10 | -10° | 5.30 | 4.30 | |
|
GWH24AGDXE-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.95 | -10° | 6.20 | 4.70 | |
|
GWH24ALEXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 6.20 | 4.70 | |
|
RXF60D9 / FTXF60D
RXF
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -10° | 6.00 | 4.80 | |
|
RXF60D9 / FTXF60F
RXF
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -10° | 6.00 | 4.80 | |
|
MOX230-12HFN8-QRD0W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-1
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KSD-35 DR14-2
ZEN Console
|
KAYSUN | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
XDMX-035N-09M25/YDAX-035H-09M25
XDMX
|
AIRWELL | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-2
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CU-UZ35ZKE / CS-UZ35ZKE
2023
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
42QTD024D8S*/38QUS024D8S*
Cassette
|
CARRIER | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
KC270HIDS8/AIC270HIDS8
Cassette
|
RIELLO | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
AS105S2SF2FA-2/1U105S2SS1FA
Wall mounted - Flair Plus
|
HAIER | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 9.00 | 7.20 | |
|
AS105S2SF2FA-2/1U105S2SQ1FA
Wall mounted - F
|
HAIER | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -10° | 9.00 | 7.20 | |
|
MOX301-18HFN8-QRD0GW/MSXTBU-18HRFN8-QRD0GW
XT R32
|
MIDEA | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.30 | -10° | 5.30 | 4.10 | |
|
KAE-S 52 DR9/KAY-D 52 DR11
SUITE Onnix 2.0
|
KAYSUN | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.30 | -10° | 5.30 | 4.10 | |
|
MOF-18N8D0/MXT-18N8-1
XT R32
|
MIDEA | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.30 | -10° | 5.30 | 4.10 | |
|
RZAG60A / FDXM60F9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
RZAG60A / FNA60A9
RZAG
|
DAIKIN | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.90 | 3.30 | -20° | 6.00 | 4.50 | |
|
CU-TZ71WKE / CS-TZ71WKEW
2019
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.51 | -15° | 7.10 | 5.50 | |
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
RAC-DJ70WHAE / RAK-DJ70RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.10 | -15° | 7.10 | 5.40 |