Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(1)
AUX
(0)
BOSCH
(26)
BRYANT
(0)
Buderus
(6)
CARRIER
(9)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(89)
EQUATION
(0)
FUJI ELECTRIC
(9)
FUJITSU
(24)
Fujitsu Atlantic
(15)
GENERAL
(30)
GREE
(2)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(24)
HITACHI
(8)
IVT
(2)
Inventor
(2)
KAYSUN
(0)
LG
(12)
MIDEA
(17)
MITSUBISHI ELECTRIC
(18)
Mitsubishi Heavy Industries
(18)
NORD
(0)
Nobu
(0)
PANASONIC
(28)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(14)
THERMOR
(0)
TOSHIBA
(32)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RXJ20A / FTXJ20AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CS
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CB
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXA20A8 / FTXA20CW
RXA
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A9 / FTXJ20AW
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A9 / FTXJ20AB
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A9 / FTXJ20AS
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A9 / FTXJ20AW9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A9 / FTXJ20AB9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
RXJ20A9 / FTXJ20AS9
RXJ
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -10° | 2.00 | 2.40 | |
|
THRVO-12/THRVI-12WFI
Thora
|
Inventor | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-QRE1GW/MSOPBU-12HRFN8-QRE1GW
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-OPP/MSOPP-12HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-OPP/MSOPP-12HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
OP-12RE1H-O/OP-12RE1-I
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
RAS-10J2AVSG-E1/RAS-B10G3KVSG-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 4.57 | -15° | 2.50 | 2.50 | |
|
RAS-10J2AVSG-E1/RAS-B10G3KVSGB-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 4.57 | -15° | 2.50 | 2.50 | |
|
38WHSH025A1A0TEE/40WHHW025D1A0TEE
40WHH
|
CARRIER | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 4.57 | -15° | 2.50 | 2.50 | |
|
38WHSH025A1A0TEE/40WHHB025D1A0TEE
40WHH
|
CARRIER | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 4.57 | -15° | 2.50 | 2.50 | |
|
AOYG07KGCB/ASYG07KGTF
ASY**K
|
FUJITSU | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.30 | 5.00 | -15° | 2.00 | 2.30 | |
|
AOHG07KGCB/ASHG07KGTF
ASH**K
|
GENERAL | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.30 | 5.00 | -15° | 2.00 | 2.30 | |
|
ROG07KGCB/RSG07KGTF
RS**K
|
FUJI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.30 | 5.00 | -15° | 2.00 | 2.30 | |
|
AOYG07KGCB/ASYG07KGTF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.30 | 5.00 | -15° | 2.00 | 2.30 | |
|
CL7000i 20 E / CL7000iU W 20 E
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
CL7000i 20 E / CL7000iU W 20 ES
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
CL7000i 20 E / CL7000iU W 20 EB
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC186i.3-2,0 / AC186i.3-2,0 W
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC186i.3-2,0 / AC186i.3-2,0 WB
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
MOX230-07HFN8-QRE1W/MSOPBU-07HRFN8-QRE1W
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
MOX330-12HFN8-QRE1GW/MSOPBU-12HRFN8-QRE1GWV
Oasis Plus
|
MIDEA | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HE
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HES
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HEB
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 704 O / Aero 704 I
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 704 O / Aero 704 IB
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
MOX330-12HFN8-QRE3GW/MSOPBU-12HRFN8-QRE3GW
Oasis Plus
|
MIDEA | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.71 | -10° | 3.50 | 2.10 | |
|
MOX330-09HFN8-QRE3GW/MSOPBU-09HRFN8-QRE3GW
Oasis Plus
|
MIDEA | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.30 | 5.10 | 4.71 | -10° | 2.60 | 2.10 | |
|
GWH12AKCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.49 | -10° | 3.53 | 3.20 | |
|
H12S1P NS1/H12S1P U18
U18A
|
LG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.71 | -10° | 3.50 | 2.80 | |
|
H12S1PA NS1 / H12S1PA U18
U18A
|
LG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.71 | -10° | 3.50 | 2.80 | |
|
AA12SP U18 / AA12SP NS1
U18A
|
LG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.71 | -10° | 3.50 | 2.80 | |
|
AA12SB NS1 / AA12SP U18
U18A
|
LG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.71 | -10° | 3.50 | 2.80 | |
|
SRC20ZT-W/SRC20ZT-WF
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 5.09 | -10° | 2.00 | 2.60 | |
|
SRC20ZT-W/SRC20ZT-WFB
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 5.09 | -10° | 2.00 | 2.60 | |
|
SRC20ZT-W/SRC20ZT-WFT
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 5.09 | -10° | 2.00 | 2.60 | |
|
GWH09AKCXD-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 4.73 | -10° | 2.70 | 3.00 | |
|
SRC25ZT-W/SRC25ZT-WF
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.57 | -10° | 2.50 | 2.70 |