Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(81)
ATLANTIC
(36)
AUX
(145)
BOSCH
(131)
BRYANT
(6)
Buderus
(34)
CARRIER
(137)
CIAT
(33)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(418)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(118)
FUJITSU
(271)
Fujitsu Atlantic
(137)
GENERAL
(188)
GREE
(136)
GSS
(4)
HAIER
(357)
HEC
(5)
HEIWA
(7)
HISENSE
(380)
HITACHI
(127)
IVT
(10)
Inventor
(116)
KAYSUN
(50)
LG
(260)
MIDEA
(696)
MITSUBISHI ELECTRIC
(432)
Mitsubishi Heavy Industries
(196)
NORD
(52)
Nobu
(8)
PANASONIC
(243)
PITSOS
(6)
RIELLO
(35)
Rotenso
(0)
SAMSUNG
(167)
THERMOR
(44)
TOSHIBA
(236)
Viessmann
(24)
Vulcano
(14)
WESTPOINT
(24)
XTRON
(4)
YORK
(29)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR70F12C1DBN/AR70F12C1DBX
RAC
|
SAMSUNG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
PUZ-ZM71VHA2/SEZ-M71DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA2/SEZ-M71DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/SEZ-M71DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 4.00 | 3.90 | -20° | 7.10 | 4.70 | |
|
M4OA-27HFN8-Q(HRU)/MCA4U-09HRFNX-QRD1W(GA)+MCA4U-18HRFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 7.90 | 6.30 | |
|
MUZ-WN35VA/MSZ-WN35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -15° | 3.10 | 2.40 | |
|
42HU18VDS8C/38HU18VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
SC250HIDS8/AIC250HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
42QZL018D8S*/38QUS018D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
ARXC60D / ATXC60D
ARXC
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.38 | 4.19 | 3.71 | -14° | 6.21 | 4.10 | |
|
CU-TZ42CKE / CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.73 | -15° | 4.20 | 3.60 | |
|
ARXF42E / ATXF42E
ARXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 4.25 | 3.71 | -15° | 4.20 | 3.30 | |
|
ARXF42F / ATXF42F
ARXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 4.25 | 3.71 | -15° | 4.20 | 3.30 | |
|
42QTD036D8S*/38QUS036D8T*
Cassette
|
CARRIER | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
KC210HIDS8/AIC210HIDT8
Cassette
|
RIELLO | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100TFP105
Cassette
|
Viessmann | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
S3UM12EL26A / S3NM12EL26A
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA1 U18 / A12GA1 NSE
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18 / A12GA2 NSE
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2U EEU / A12GA2N EEU
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18T / A12GA2 NSET
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
ARXF35F / ATXF35F
ARXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
SRC20ZTL-W/SRK20ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.40 | 4.22 | -10° | 2.00 | 2.40 | |
|
SUZ-M71VA/SFZ-M71VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/SFZ-M71VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.80 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
PUZ-ZM50VKA2/SLZ-M50FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/SLZ-M50FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.40 | -11° | 5.00 | 3.80 | |
|
ARXF25F / ATXF25F
ARXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
CU-UZ50WKE / CS-UZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-FZ50WKE / CS-FZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-BZ50XKE / CS-BZ50XKE
2022
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 4.70 | 4.00 | |
|
CU-UZ50ZKE / CS-UZ50ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
MOX103-12HFNX-QRD1GW/MSCB1BU-12HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
CB1-12HFNX-O/CB1-12HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
MOM-12N8D0/MCB1-12N8
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
MOX103-12HFN8-QRD1GW/MSCB1BU-12HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
CB1-12HFNX-O(B) /CB1-12HRFN8-I(B)
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
CB1-12HFNX-O(A) /CB1-12HRFN8-I(A)
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
MOM-12NXD0/MCB1-12N8
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
CB1-12HFNX-O(R)/CB1-12HRFN8-I(R)
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
CB1-12HFNX-O-GR/CB1-12HRFN8-I-GR
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
CB1-12HFNX-O/CB1-12HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.20 | 3.65 | -10° | 3.60 | 2.60 | |
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 |