Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(81)
ATLANTIC
(36)
AUX
(70)
BOSCH
(121)
BRYANT
(6)
Buderus
(34)
CARRIER
(127)
CIAT
(33)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(418)
EQUATION
(5)
FUJI ELECTRIC
(118)
FUJITSU
(271)
Fujitsu Atlantic
(137)
GENERAL
(188)
GREE
(119)
GSS
(4)
HAIER
(360)
HEC
(5)
HEIWA
(7)
HISENSE
(314)
HITACHI
(127)
IVT
(10)
Inventor
(116)
KAYSUN
(46)
LG
(254)
MIDEA
(695)
MITSUBISHI ELECTRIC
(432)
Mitsubishi Heavy Industries
(196)
NORD
(52)
Nobu
(8)
PANASONIC
(243)
RIELLO
(35)
Rotenso
(0)
SAMSUNG
(167)
THERMOR
(44)
TOSHIBA
(236)
Viessmann
(24)
Vulcano
(14)
WESTPOINT
(22)
YORK
(29)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYH30KMTB/ASYH30KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AD50S2SS1FA/1U50S2SJ2FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.73 | -10° | 5.00 | 4.30 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
UUB1 U20 / UM18FH NA0
UU
|
LG | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -10° | 5.00 | 4.40 | |
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
AS25XCAHRA+AS25XCAHRA/2U40S2SM1FA
Super Match Multi-Tundra
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
AS25XCAHRA-MB+AS25XCAHRA-MB/2U40S2SM1FA
Super Match Multi-Expert
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
AOYG36KBTB/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KBTB/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RYG36KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KRTA/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KRTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KBTB/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AD71S2SS1FA(H)/1U71S2SR3FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.73 | -10° | 7.10 | 5.00 | |
|
AUW60U4RJ7/AVT60UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.80 | -10° | 6.20 | 5.50 | |
|
SCM30ZS-W/SRK15ZS-WF/SRK15ZS-WF
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.07 | 4.80 | 5.41 | -10° | 3.00 | 3.30 | |
|
RXA50B / FTXA50AW
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BS
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BT
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RXA50B / FTXA50BB
RXA
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -15° | 5.00 | 4.00 | |
|
RZAG50B / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -10° | 5.00 | 4.00 | |
|
U-36PZ3E5 / S-36PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.29 | -15° | 3.60 | 2.80 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEG24KMTA/ASEG24KMTE
ASE**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
RAV-GM901ATP-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
GWH09AVCXB-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
AS50KBAHRA-MW/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
AS50KBAHRA-MB/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
AS50KBAHRA-W/1U50KS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 3.71 | -10° | 5.00 | 4.60 | |
|
U-60PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.27 | -15° | 6.10 | 4.60 | |
|
RZASG71MV1 / FCAG35B / FCAG35B
RZASG
|
DAIKIN | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.05 | 4.31 | 4.31 | -10° | 6.80 | 4.50 | |
|
AOYG14KBTB/AUXG14KVLA
AUY**K
|
FUJITSU | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG14KBTB/AUXG14KVLA
AUH**K
|
GENERAL | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
ROG14KBTB/RCG14KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/AUXG14KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
GWH24AUDXF-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
GWH24AUDXF-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
HMIP2-70W-EUV1 / HMEP2-70-EUV1
HYOKO2
|
HEIWA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 |