Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(38)
AUX
(145)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(140)
CIAT
(36)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(522)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(139)
GSS
(4)
HAIER
(442)
HEC
(5)
HEIWA
(8)
HISENSE
(380)
HITACHI
(147)
IVT
(10)
Inventor
(124)
KAYSUN
(51)
LG
(297)
MIDEA
(729)
MITSUBISHI ELECTRIC
(446)
Mitsubishi Heavy Industries
(201)
NORD
(52)
Nobu
(8)
PANASONIC
(253)
PITSOS
(6)
RIELLO
(38)
Rotenso
(0)
SAMSUNG
(187)
THERMOR
(58)
TOSHIBA
(238)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(31)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAC-60NPE / RAK-60RPE
RAC-NPE(D)
|
HITACHI | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.61 | 3.80 | -15° | 6.00 | 4.70 | |
|
UUB1 U20 / UV30F N10
UU
|
LG | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.23 | -10° | 7.50 | 4.40 | |
|
RAV-GM1102AT8W-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.15 | 4.29 | 3.97 | -15° | 9.50 | 8.00 | |
|
FDC100VNA-W/SRK100ZR-W
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.22 | 4.33 | 3.68 | -20° | 10.00 | 8.50 | |
|
MU2RW15 U12 / MJ07PC NSJ / MJ07PC NSJ
MU
|
LG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.40 | -15° | 4.10 | 4.10 | |
|
FDC100VNA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
GWH12AUCXD-K6DNA2F
MONOSPLITS
|
GREE | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.01 | -10° | 3.50 | 2.80 | |
|
PUZ-ZM35VKA2/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
SRC35ZS-W2/SRF35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.70 | 4.02 | -10° | 3.50 | 2.90 | |
|
NB71CEAHRA/1N71WEAFRA-W
NORD - Cassette
|
NORD | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 7.10 | 5.50 | |
|
NB71CEAHRA/1N71WEAFRA
NORD - Cassette
|
NORD | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 7.10 | 5.50 | |
|
M2OF-18HFN8-Q/MSAGBU-09HRFN8-QRD1GW(GA)+MSAGBU-09HRFN8-QRD1GW(GA)
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL5000iU W 26 E +CL5000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL4000iU W 26 E +CL4000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
RAS-4HNC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
FDC100VNA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
SRC25ZS-W2/SRK25ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
SRC25ZS-W2/SRK25ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
SRC25ZS-W2/SRK25ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
SRC25ZS-W2/SRK25ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
GWH09ATCXB-K5DNA1B
MONOSPLITS
|
GREE | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.40 | -10° | 2.70 | 2.70 | |
|
AUW40U4RJ8/ACT40UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.00 | -10° | 4.10 | 4.00 | |
|
AUW52U4RJ8/ACT52UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 3.71 | -10° | 5.00 | 4.00 | |
|
AD50S2SS1FA/1U50S2SJ2FA-2
Slim Duct Low Pressure-Monosplit
|
HAIER | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.73 | -10° | 5.00 | 4.30 | |
|
MOX231-09HFN8-QRD6GW/MSGPAU-09HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
MOX231-09HFN8-QRD6GW/MSEZAU-09HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
EZ-09RD6-O/EZ-09RD6-I
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
EZ-09RD6H-O/EZ-09RD6-I
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
EZ-09RD6-O/EZB-09RD6-I
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
EZ-09RD6H-O/EZB-09RD6-I
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MW/1U25DEBFRA-S
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MB/1U25DEBFRA-S
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MWV/1U25DEBFRA-SH
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MW/1U25DEBFRA-SH
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MB/1U25DEBFRA-SH
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
HDMC-025N-09M25/YDA*-025*-09M25
Harmonia
|
AIRWELL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
MOX2-09CFN8CF/MSEZ-09CFN8CF
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
WIMO-09325.MH / WIM-09325.MH
WIM 325
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
UI 2,6 kW MURAO PREMIUM BLANC & UE MONO 2,6 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
UI 2,6 kW MURAO PREMIUM NOIR & UE MONO 2,6 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
INVO-09/INVI-09WFI
Intellia
|
Inventor | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
AIRGRN-09HFN8-O/AIRGRN-09HRFN8-I V1
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
LINEPRO-09HFN8-O/LINEPRO-09HRFN8-I
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
MOX2-09HFN8CF/MSEZ-09HFN8CF
Solstice
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 |