Filters · 3 active
Manufacturer:
CARRIER
GENERAL
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(4)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CIAT
(9)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(120)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(122)
Fujitsu Atlantic
(59)
GREE
(4)
GSS
(0)
HAIER
(97)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(42)
IVT
(0)
Inventor
(25)
KAYSUN
(24)
LG
(77)
MIDEA
(125)
MITSUBISHI ELECTRIC
(138)
Mitsubishi Heavy Industries
(190)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(7)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG36KBTB/ARXG36KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KHTAP
ARXG**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
42QZL036D8S*/38QUS036D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
42QFD048D8S*/38QUS048D8T*
Floor Standing
|
CARRIER | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.74 | 14.60 | 11.00 | ||
|
AOHG36KBTB/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG45KBTB/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOHG45KRTA/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOHG36KBTB/AUXG36KRLB
AUH**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
42QSV048D8S/38QUS048D8TX
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
42QSV048D8S/38QUS048D8S
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
AOHG54KBTB/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOHG54KRTA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
42QSS042D8S*/38QUS042D8S*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
AOHG36KBTB/ARXG36KMLA
ARH**K
|
GENERAL | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
42QSV042D8S/38QUS042D8S
Duct R32
|
CARRIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
42QSS048D8S*/38QUS048D8T*
Ducted
|
CARRIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
AOHG45KBTB/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
42QSS036D8S*/38QUS036D8T*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
42QSV036D8S*/38QUS036D8T*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
AOHG45KRTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOHG45LATT/AUHG45LRLA
AOHG**L
|
GENERAL | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOHG54KRTA/ARXH54KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
42QZL036D8S*/38QUS036D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42QZL048D8S/38QUS048D8S
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
42QZL048D8S*/38QUS048D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
42QTD060D8S*/38QUS060D8T*
Cassette
|
CARRIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.21 | 15.00 | 11.80 | ||
|
42QTD048D8S/38QUS048D8S
Cassette
|
CARRIER | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
AOHG45KBTB/ARXG45KHTA
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXG45KHTB
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTA
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTB
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG36KATA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG54LATT/AUHG54LRLA
AOHG**L
|
GENERAL | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.09 | 3.61 | 14.00 | 10.40 | ||
|
42QTD042D8S*/38QUS042D8S*
Cassette
|
CARRIER | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 | ||
|
AOHG45LATT/ABHG45LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
AOHG36KATA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/ARXH36KMTAP
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
42QZL048D8S/38QUS048D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
42QZL060D8S/38QUS060D8TX
Ceiling suspended
|
CARRIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
42QTD048D8S*/38QUS048D8T*
Cassette
|
CARRIER | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.49 | 14.00 | 10.80 | ||
|
AOHG45KBTB/ARXG45KHTAP
ARX**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 |