Filters · 3 active
Manufacturer:
GENERAL
HITACHI
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(4)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(20)
CIAT
(9)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(120)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(122)
Fujitsu Atlantic
(59)
GREE
(4)
GSS
(0)
HAIER
(97)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
IVT
(0)
Inventor
(25)
KAYSUN
(24)
LG
(77)
MIDEA
(125)
MITSUBISHI ELECTRIC
(138)
Mitsubishi Heavy Industries
(190)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(7)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAS-4HVRC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.93 | 4.36 | 4.23 | -20° | 10.00 | 8.70 | |
|
RAS-4HVNC2E / RCI-4.0FS1R
UTOPIA PRIME
|
HITACHI | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
AOHG36KBTB/ARXG36KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KHTAP
ARXG**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
RAS-4HVRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-4HRC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.62 | 4.36 | 4.23 | -20° | 10.00 | 8.70 | |
|
RAS-4HVNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-5HVRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
AOHG36KBTB/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ABHG36KRTA
ABH**K
|
GENERAL | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
RAS-4HNC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.40 | 4.30 | -20° | 10.00 | 8.70 | |
|
RAS-4HRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
AOHG36KBTB/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
RAS-5HRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.89 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
AOHG45KBTB/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOHG45KRTA/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
RAS-5HVRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.26 | 3.98 | -20° | 11.90 | 11.93 | |
|
AOHG36KBTB/AUXG36KRLB
AUH**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
RAS-4HNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.96 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.25 | 3.98 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.24 | 3.98 | -20° | 11.90 | 11.93 | |
|
AOHG54KBTB/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOHG54KRTA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
RAS-5HNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.13 | 4.23 | 3.98 | -20° | 11.90 | 11.93 | |
|
AOHG36KBTB/ARXG36KMLA
ARH**K
|
GENERAL | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
RAS-4HVRC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.93 | 4.13 | 3.47 | -20° | 10.00 | 8.70 | |
|
RAS-5HVRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.09 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
AOHG45KBTB/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXH45KMTAP
ARX**K
|
GENERAL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
RAS-4HVNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.72 | 4.18 | 3.53 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
AOHG45KRTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOHG45LATT/AUHG45LRLA
AOHG**L
|
GENERAL | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
RAS-5HVNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
AOHG54KRTA/ARXH54KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
RAS-4HRC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.12 | 3.47 | -20° | 10.00 | 8.70 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-4HNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.51 | 4.17 | 3.53 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.67 | 4.09 | 3.21 | -20° | 11.90 | 11.93 |