Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(10)
Fujitsu Atlantic
(7)
GENERAL
(7)
GREE
(0)
GSS
(0)
HAIER
(11)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(17)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(81)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC140VSA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC140VNA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC125VNA/FDT60VH/FDT60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.97 | 5.21 | 4.23 | 12.50 | 9.80 | ||
|
FDC125VSA/FDT60VH/FDT60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.97 | 5.21 | 4.23 | 12.50 | 9.80 | ||
|
FDC140VNA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC125VNA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC140VNA/FDT71VH/FDT71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.51 | 4.89 | 4.17 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT71VH/FDT71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.51 | 4.89 | 4.17 | 13.60 | 10.50 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC100VNA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.26 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC100VNA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC125VNX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.26 | 3.83 | 12.50 | 11.40 | ||
|
FDC100VNA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC125VNX/FDT60VH/FDT60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.83 | 4.46 | 4.35 | 12.50 | 11.40 | ||
|
FDC125VNX/SRK60ZSX-W/SRK60ZSX-W
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.56 | 4.02 | 12.50 | 11.40 | ||
|
FDC125VSX/SRK60ZSX-W/SRK60ZSX-W
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.56 | 4.02 | 12.50 | 11.40 | ||
|
FDC100VNA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC125VNX/FDE60VH/FDE60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.45 | 4.13 | 3.78 | 12.50 | 11.40 | ||
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC125VSA/FDT125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.38 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VNA/FDT125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.38 | 3.74 | 12.50 | 9.80 | ||
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
FDC100VNX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.18 | 4.18 | -20° | 10.00 | 11.20 | |
|
FDC125VNA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC125VSA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
FDC100VNX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VSX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FDC100VNX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 |