Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(1)
Fujitsu Atlantic
(1)
GENERAL
(1)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(6)
IVT
(0)
Inventor
(1)
KAYSUN
(1)
LG
(2)
MIDEA
(6)
MITSUBISHI ELECTRIC
(3)
Mitsubishi Heavy Industries
(38)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(7)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC125VSX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.94 | 4.36 | 2.91 | 12.50 | 14.00 | ||
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
PUZ-M200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.20 | 3.30 | -20° | 19.00 | 15.50 | |
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
FDC200VSA/SRK100ZR-W/SRK100ZR-W
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.67 | 3.02 | 19.00 | 12.50 | ||
|
FDC250VSA-W/FDF125VH/FDF125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDF125VH1/FDF125VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
FDC140VNX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.17 | 2.90 | 14.00 | 13.00 | ||
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
FDC125VSX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.02 | 2.60 | 12.50 | 14.00 | ||
|
FDC140VNX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
FDC140VSX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
MOX630U-55HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.00 | -10° | 15.80 | 12.20 | |
|
FDC140VSX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 3.96 | 2.50 | 14.00 | 15.50 | ||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
FDC140VNX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDU140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 | ||
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOHG72LRLA/ARHG72LHTA
AOHG**L
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
ROG72LRLA/RDG72LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
FDC140VNX-W/FDF140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.81 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDF140VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.81 | 3.41 | 14.00 | 13.00 | ||
|
42HU60VDS8C/38HU60VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
42QZL060D8S*/38QUS060D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
SC217HIDS8/AIC217HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
FDC140VSX-W/FDF140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.72 | 3.41 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDF140VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.72 | 3.41 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.88 | 2.63 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDU140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.88 | 2.63 | 14.00 | 15.50 | ||
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.36 | 3.95 | 3.33 | -10° | 23.50 | 12.30 | |
|
MOX630U-55HFN8-RRD0W(GA)/MFM-55HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MO-55N8-R-1/MFM-55N8
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-R(GA)/MFM-55HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-R OUT V1/MFM-55HRFN8-Q IN V1
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
KUE-160 DTR14/KPV-160 DR14
Zen
|
KAYSUN | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-55HFN8-RRD0W(GA)-GR/MFM-55HRFN8-QRD0W-GR
Floor Standing R32
|
MIDEA | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 |