Filters · 3 active
Manufacturer:
DAIKIN
PANASONIC
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RXM25A9 / FVXM25B
RXM
|
DAIKIN | Floor standing | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.64 | 4.70 | 4.53 | -20° | 2.40 | 2.30 | |
|
CU-Z25ZKE / CS-Z25ZKEW
2023
|
PANASONIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.86 | -20° | 2.50 | 2.60 | |
|
CU-Z25ZKE / CS-XZ25ZKEW
2023
|
PANASONIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.86 | -20° | 2.50 | 2.60 | |
|
CU-Z25ZKE / CS-XZ25ZKEW-H
2023
|
PANASONIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.86 | -20° | 2.50 | 2.60 | |
|
CU-Z25CKE / CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.86 | -20° | 2.50 | 2.60 | |
|
CU-Z25CKE / CS-XZ25CKEW
2025
|
PANASONIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.86 | -20° | 2.50 | 2.60 | |
|
CU-Z25CKE / CS-XZ25CKEW-H
2025
|
PANASONIC | Wall mounted | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.86 | -20° | 2.50 | 2.60 | |
|
RXM25A9 / FTXM25A
RXM
|
DAIKIN | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -20° | 2.50 | 2.40 | |
|
RXM25A9 / FTXM25A
RXM
|
DAIKIN | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -20° | 2.50 | 2.40 | |
|
U-36PZ3E5/S-3650PU3E
2019
|
PANASONIC | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.80 | 5.07 | -15° | 3.60 | 2.80 | |
|
CU-Z35ZKE / CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.55 | -20° | 3.50 | 2.90 | |
|
CU-Z35ZKE / CS-XZ35ZKEW
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.55 | -20° | 3.50 | 2.90 | |
|
CU-Z35ZKE / CS-XZ35ZKEW-H
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.55 | -20° | 3.50 | 2.90 | |
|
CU-Z35CKE / CS-XZ35CKEW-H
2025
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.55 | -20° | 3.50 | 2.90 | |
|
CU-Z35CKE / CS-Z35CKEW
2025
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.55 | -20° | 3.50 | 2.90 | |
|
CU-Z35CKE / CS-XZ35CKEW
2025
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.55 | -20° | 3.50 | 2.90 | |
|
RXM35A9 / FTXM35A
RXM
|
DAIKIN | Wall mounted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -20° | 3.50 | 2.50 | |
|
RXM35A9 / FTXM35A
RXM
|
DAIKIN | Wall mounted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -20° | 3.50 | 2.50 | |
|
CU-Z25XKE / CS-Z25XKEW
2021
|
PANASONIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.20 | 4.86 | -15° | 2.50 | 2.40 | |
|
CU-Z25XKE / CS-XZ25XKEW
2021
|
PANASONIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.20 | 4.86 | -15° | 2.50 | 2.40 | |
|
CU-Z35XKE / CS-Z35XKEW
2021
|
PANASONIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.44 | -15° | 3.50 | 2.80 | |
|
CU-Z35XKE / CS-XZ35XKEW
2021
|
PANASONIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 4.44 | -15° | 3.50 | 2.80 | |
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
RXM20A / FTXM20A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.00 | 2.30 | |
|
RXA20A9 / FTXA20AW
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXA20A9 / FTXA20BB
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXA20A9 / FTXA20BS
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXA20A9 / FTXA20BT
RXA
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.15 | 5.00 | -15° | 2.00 | 2.40 | |
|
RXM25A / FTXM25A
RXM
|
DAIKIN | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.47 | 5.20 | 5.00 | -10° | 2.50 | 2.40 | |
|
RXA25A9 / FTXA25AW
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXA25A9 / FTXA25BB
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXA25A9 / FTXA25BS
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXA25A9 / FTXA25BT
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.15 | 5.00 | -15° | 2.50 | 2.45 | |
|
RXM25R9 / FVXM25A
RXM
|
DAIKIN | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.65 | 4.55 | -15° | 2.40 | 2.30 | |
|
RXM25R9 / FVXM25A9
RXM
|
DAIKIN | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.65 | 4.55 | -15° | 2.40 | 2.30 | |
|
RXA35A9 / FTXA35AW
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.73 | 5.15 | 4.04 | -15° | 3.40 | 2.50 | |
|
RXA35A9 / FTXA35BB
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.73 | 5.15 | 4.04 | -15° | 3.40 | 2.50 | |
|
RXA35A9 / FTXA35BS
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.73 | 5.15 | 4.04 | -15° | 3.40 | 2.50 | |
|
RXA35A9 / FTXA35BT
RXA
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.73 | 5.15 | 4.04 | -15° | 3.40 | 2.50 | |
|
RXM35A / FTXM35A
RXM
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.20 | 4.55 | -10° | 3.50 | 2.50 | |
|
CU-Z25CBEA / CS-Z25CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.47 | -15° | 2.50 | 2.70 | |
|
RXM20R9 / FTXM20R
RXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.10 | 5.00 | -20° | 2.00 | 2.30 | |
|
ARXM25A / ATXM25A
ARXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.30 | 5.15 | 5.00 | -10° | 2.50 | 2.40 | |
|
RXM25R9 / FTXM25R
RXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.10 | 5.00 | -20° | 2.50 | 2.40 | |
|
RXM35R9 / FTXM35R
RXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.65 | 5.10 | 4.04 | -20° | 3.40 | 2.50 | |
|
ARXM35A / ATXM35A
ARXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.15 | 4.45 | -10° | 3.50 | 2.50 | |
|
ARXM35A9 / ATXM35A
ARXM
|
DAIKIN | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.15 | 4.45 | -10° | 3.50 | 2.50 | |
|
ARXM25R9 / ATXM25R
ARXM
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 5.10 | 5.00 | -20° | 2.50 | 2.40 | |
|
ARXM35R9 / ATXM35R
ARXM
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 5.10 | 4.04 | -20° | 3.40 | 2.50 | |
|
CU-Z20ZKE / CS-Z20ZKEW
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 |