Filters · 4 active
Manufacturer:
Candy
IVT
THERMOR
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
Aero 503 O CN / Aero 503 I CN
Aero 500
|
IVT | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
NAGANO GAINABLE MP IG35MP-NG / E1U35LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 3.50 | 2.70 | |
|
Aero 603-1 O / Aero 603-1 I
Aero 600-1
|
IVT | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
NAGANO U.I 2000W R32 / E1U20LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO U.I 2600W R32 / E1U26LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE IM20V2-NG / E1U20LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE IM26V2-NG / E1U26LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE NOIRE IM20V2-NGN / E1U20LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE NOIRE IM26V2-NGN / E1U26LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
CY-09QBIN-A/CY-09QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 2.70 | 2.40 | |
|
NAGANO MURALE PURE IM20V3-NG / E1U20LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE IM26V3-NG / E1U26LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE NOIRE IM20V3-NGN / E1U20LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
NAGANO MURALE PURE NOIRE IM26V3-NGN / E1U26LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
Aero 604-1 O / Aero 604-1 I
Aero 600-1
|
IVT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
NAGANO U.I 3500W R32 / E1U35LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE IM35V2-NG / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE NOIRE IM35V2-NGN / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
CY-12QBIN-A/CY-12QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 3.30 | 2.80 | |
|
NAGANO MURALE PURE IM35V3-NG / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE NOIRE IM35V3-NGN / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
NAGANO CONSOLE IC26V3-NG / E1U26LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
NAGANO GAINABLE BP IG25BP-NG/E1U26LV2-NG
NAGANO GAINABLE BASSE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
CY-09RAIN-A/CY-09RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
CY-2H14AOUT/CY-09BRIN/CY-12BRIN
CANDY - R Multi
|
Candy | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.00 | -10° | 3.60 | 2.90 | |
|
NISEKO MURALE IM20-NS / E1U20L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
NISEKO MURALE IM26-NS / E1U26L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
CY-12RBW-IN/
CANDY - R-
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.10 | -10° | 3.00 | 2.40 | |
|
CY-12BRIN/CY-12BROUT
Candy Brezza 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.50 | |
|
CY-12BRIN-N/CY-12BROUT-N
Candy Brezza 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.40 | -10° | 3.20 | 2.50 | |
|
NISEKO MURALE IM35-NS / E1U35L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
NAGANO CASSETTE IK26-F66-NG/E1U26LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 |