Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(5)
ATLANTIC
(0)
AUX
(4)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(6)
EQUATION
(0)
FUJI ELECTRIC
(3)
FUJITSU
(8)
Fujitsu Atlantic
(4)
GENERAL
(4)
GREE
(0)
GSS
(0)
HAIER
(13)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(2)
IVT
(1)
Inventor
(4)
KAYSUN
(6)
LG
(11)
MIDEA
(24)
MITSUBISHI ELECTRIC
(23)
Mitsubishi Heavy Industries
(1)
NORD
(3)
Nobu
(0)
PANASONIC
(7)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(7)
THERMOR
(4)
TOSHIBA
(11)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
RAV-GM402ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 5.13 | 5.13 | -15° | 3.60 | 2.70 | |
|
NF25DBAHRA/1N25MEAFRA
NORD - Console
|
NORD | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
CU-Z25CBEA / CS-Z25CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.47 | -15° | 2.50 | 2.70 | |
|
NF35DBAHRA/1N35MEAFRA
NORD - Console
|
NORD | Console | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-09HFN8-QRD6W(GA)/MFA2U-09HRFN8-QRD6W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX230-09AFN8-QRD6W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX230-09HFN8-QRD6W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
CL5100i CNO 25 HE / CL5100i CN 25 HE
Climate 5100i
|
BOSCH | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
Aero 503 O CN / Aero 503 I CN
Aero 500
|
IVT | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
AOYG09KBTB/ARXG09KLLAP
ARY**K
|
FUJITSU | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/ARXG09KLLAP
ARH**K
|
GENERAL | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RDG09KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/ARXG09KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
PUZ-ZM35VKA3/PEAD-M35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.20 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PEAD-M35JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.20 | -11° | 3.60 | 2.40 | |
|
CU-Z25CBEA / CS-Z25CD3EAW
2025
|
PANASONIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
U-36PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.61 | -15° | 3.50 | 2.80 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
MOX230-12HFN8-QRD0W(GA)/MTJ-12HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MTJU-12HNX
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KPD-35 DR15
Duct R32
|
KAYSUN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
DDMD-035N-09M25/YDAX-035H-09M25**
DDMD
|
AIRWELL | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
42QSV012D8S*/38QUS012D8S-1
Ducted
|
CARRIER | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7iDI-12WiFiR
Ducted R32
|
Inventor | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
UUA1 UL0 / UV18F N10
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 3.70 | -10° | 5.00 | 2.90 | |
|
RAV-GM401ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.34 | 5.10 | 5.13 | -15° | 3.60 | 2.70 | |
|
AD35S2SM3FA(H)/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.71 | -10° | 3.50 | 2.70 | |
|
PUZ-ZM35VKA2/PEAD-M35JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
CU-Z35CBEA / CS-Z35CD3EAW
2025
|
PANASONIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.82 | -15° | 3.50 | 2.80 | |
|
MOX230-09HFN8-QRD1W(GA)/MTJ-09HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOX230-09HFN8-Q(GA)/MTJ-09HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MO-09N8-Q/MTJU-09HNX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
KUE-26 DVR14/KPD-26 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
DDMD-025N-09M25/YDAX-025R-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
SUZ-M35VA/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 3.60 | 2.60 |