Filters · 3 active
Manufacturer:
ATLANTIC
KAYSUN
AIRCLASS
(1)
AIRWELL
(21)
AUX
(21)
BOSCH
(41)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
LG
(75)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
2U 018 NBB.UE/AS 009 JDB.UI/AS 012 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.71 | -10° | 4.60 | 4.00 | |
|
UI 4,2 kW MURAO SMART BLANC & UE MONO 4,2 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 4.00 | 3.60 | |
|
UI 4,2 kW MURAO PREMIUM BLANC & UE MONO 4,2 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 4.00 | 3.60 | |
|
UI 4,2 kW MURAO PREMIUM NOIR & UE MONO 4,2 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 4.00 | 3.60 | |
|
KUE-52 DVR13/KPD-52 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
KAE-P 52 DR9/KAY-P 52 DR12
SUITE Prodigy PRO
|
KAYSUN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
KUE-52 DVR13/KPD-52 DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
KUE-52 DVR13/KCI-52 DR15
Cassette R32
|
KAYSUN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
KUE-52 DVR13/KPC-52 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
KAE-C 52 DR11/KAY-CF 52 DR12
SUITE Casual
|
KAYSUN | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
KUE-52 DVR13/KCI-52 DR14
ZEN Cassette
|
KAYSUN | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
KAE-S 52 DR9/KAY-D 52 DR11
SUITE Onnix 2.0
|
KAYSUN | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.30 | -10° | 5.30 | 4.10 | |
|
KUE-52 DVR13/KSD-52 DR14-2
ZEN Console
|
KAYSUN | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
AS 012 DBB.UI/ 1U 012 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.71 | -10° | 3.60 | 3.20 | |
|
AB 018 DB.UI/1U 018 DC.UE
Cassettes
|
ATLANTIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.42 | -10° | 5.00 | 4.00 | |
|
UI 4,9KW MURAO ACCESS BLANC/UE MONO 4,9KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
UI 3,5KW MURAO ACCESS BLANC/UE MONO 3,5KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 2.74 | -10° | 3.50 | 3.00 |