Filters · 4 active
Manufacturer:
BOSCH
Candy
SAMSUNG
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(21)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
LG
(75)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.90 | 4.38 | -25° | 5.00 | 4.10 | |
|
AC052BXAPKG/AC052BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.58 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
CL5100i CNO 35 HE / CL5100i CN 35 HE
Climate 5100i
|
BOSCH | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CL7100i 35 HE / CL7100i W 35 HE
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HES
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HEB
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
AJ050TXJ2KG / AR70F09CAAW / AR70F09CAAW
FJM
|
SAMSUNG | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.54 | 4.64 | 4.38 | -10° | 5.00 | 4.21 | |
|
CLC8001i 35 E / CLC8001i-W 35 E
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
AC052BXAPKG/AC052BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -25° | 5.00 | 3.90 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
AJ040TXJ2KG / AR70F07CAAW / AR70F07CAAW
FJM
|
SAMSUNG | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.54 | 4.64 | 4.67 | -10° | 4.00 | 3.05 | |
|
AJ040TXJ2KG / AR70H07CAAW / AR70H07CAAB
FJM
|
SAMSUNG | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.54 | 4.64 | 4.67 | -10° | 4.00 | 3.05 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CL7000i 41 E / CL7000iU W 41 E
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 ES
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 EB
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
AC071BXAPKG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
AC071BXAPNG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
AJ050HCJ2KG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.46 | 4.21 | 4.15 | -10° | 5.00 | 4.21 | |
|
AR70F24C1AWN/AR70F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1AWN/AR60F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24CAAWN/AR60F24CAAWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1KWN/AR60F24C1KWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR70F24C1DBN/AR70F24C1DBX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR80F24CAAWN/AR80F24CAAWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR70H24C1AWN/AR70H24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.73 | -11° | 6.50 | 4.10 | |
|
AR80H24CAAWN/AR80H24CAAWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR70H24CACBN/AR70H24CACBX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 | |
|
AR70H24CACWN/AR70H24CACWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 |