Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(18)
ATLANTIC
(8)
AUX
(20)
BOSCH
(16)
BRYANT
(1)
Buderus
(5)
CARRIER
(31)
CIAT
(8)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(4)
DAIKIN
(103)
EQUATION
(0)
FUJI ELECTRIC
(35)
FUJITSU
(86)
Fujitsu Atlantic
(44)
GENERAL
(50)
GREE
(27)
GSS
(1)
HAIER
(99)
HEC
(1)
HEIWA
(2)
HISENSE
(75)
HITACHI
(11)
IVT
(1)
Inventor
(26)
KAYSUN
(9)
LG
(63)
MIDEA
(151)
MITSUBISHI ELECTRIC
(69)
Mitsubishi Heavy Industries
(12)
NORD
(13)
Nobu
(2)
PANASONIC
(44)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(40)
THERMOR
(12)
TOSHIBA
(50)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
ND35MDAHRA/1N35MEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 3.50 | 3.60 | |
|
RAS-13P2AVSG-E/RAS-B13N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAS-13P2AVSG-E/RAS-B13P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAS-13P2AVSG-E/RAS-B13P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
CU-Z35CBEA / CS-Z35CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.60 | 3.98 | -15° | 3.50 | 3.20 | |
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
AUW52U4RS7/ADT52UX4RGM8
Super Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.40 | 3.82 | -10° | 5.00 | 4.00 | |
|
AUW35U4RS8/ADT35UX4RBL8
Turbo Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 4.00 | -10° | 3.50 | 3.00 | |
|
AOEG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
AUW52U4RS7/ADT52UX4RCL8
Super Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.79 | -10° | 5.00 | 4.00 | |
|
MUZ-FT35VGHZ/MSZ-FT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
MUZ-FT35VGHZ2/MSZ-FT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
MUZ-AY42VG/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VG2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
PUZ-ZM50VKA2/PLA-M50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PLA-M50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
MUZ-AY50VG/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VG2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
2AMXM50M9 / ATXM25R / ATXM25R
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25A / ATXM25A
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
U-50PZ3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.94 | -15° | 4.70 | 4.00 | |
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
SRC40ZSX-W1/FDTC40VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.37 | 3.98 | -20° | 4.00 | 4.00 | |
|
AUW35U4RS8/ACT35UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.00 | -10° | 3.50 | 3.00 | |
|
UUB1 U20 / UM18FH N10
UU
|
LG | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.89 | -10° | 5.00 | 4.40 | |
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
GWH18AUDXF-K6DNA2A
MONOSPLITS
|
GREE | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -10° | 5.30 | 4.20 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
UUB1 U20 / UT18FH NB0
UU
|
LG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.95 | -10° | 5.00 | 4.10 | |
|
RXM35R9 / FCAG35B
RXM
|
DAIKIN | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.90 | 3.77 | -15° | 3.50 | 3.32 | |
|
PUZ-ZM60VHA2/PLA-M60EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.76 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PLA-M60EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.76 | -20° | 6.10 | 4.40 | |
|
AOYH14KJCA/ASYH14KJCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOYH14KJCA/ASYH14KJCA-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA-B
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOEH14KJCA/ASEH14KJCAL
ASE**K
|
FUJITSU | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOEH14KJCA/ASEH14KJCALB
ASE**K
|
FUJITSU | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCAL
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCALB
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
MUZ-AY42VGH/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VGH2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.74 | -20° | 4.20 | 3.80 |