Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(16)
ATLANTIC
(4)
AUX
(25)
BOSCH
(14)
BRYANT
(1)
Buderus
(4)
CARRIER
(26)
CIAT
(9)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(50)
DE DIETRICH
(5)
EQUATION
(0)
FUJI ELECTRIC
(26)
FUJITSU
(63)
Fujitsu Atlantic
(34)
GENERAL
(37)
GREE
(21)
GSS
(1)
HAIER
(76)
HEC
(1)
HEIWA
(1)
HISENSE
(55)
HITACHI
(9)
IVT
(0)
Inventor
(19)
KAYSUN
(7)
LG
(53)
MIDEA
(128)
MITSUBISHI ELECTRIC
(45)
Mitsubishi Heavy Industries
(5)
NORD
(10)
Nobu
(2)
PANASONIC
(37)
PITSOS
(1)
RIELLO
(9)
Rotenso
(0)
SAMSUNG
(24)
THERMOR
(12)
TOSHIBA
(28)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(2)
XTRON
(1)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
AUW52U4RS7/ADT52UX4RCL8
Super Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.79 | -10° | 5.00 | 4.00 | |
|
RAC-XJ50WHAE / RAK-XJ50RHAE
RAC-XJ-WHAE airHome 800
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBE
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
RAC-XJ50WHBE / RAK-XJ50RHBEG
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.70 | 4.10 | -20° | 5.00 | 4.31 | |
|
MUZ-AY42VG/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VG2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY50VG/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VG2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
AOYH14KJCA/ASYH14KJCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOYH14KJCA/ASYH14KJCA-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA
ASH**K
|
GENERAL | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCA-B
ASH**K
|
GENERAL | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOEH14KJCA/ASEH14KJCAL
ASE**K
|
FUJITSU | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOEH14KJCA/ASEH14KJCALB
ASE**K
|
FUJITSU | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCAL
ASH**K
|
GENERAL | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
AOHH14KJCA/ASHH14KJCALB
ASH**K
|
GENERAL | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -20° | 4.20 | 4.00 | |
|
MUZ-AY42VGH/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VGH2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.74 | -20° | 4.20 | 3.80 | |
|
RAS-16P2AVSG-E/RAS-B16P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.72 | -20° | 4.60 | 4.00 | |
|
RAS-16P2AVSG-E/RAS-B16P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.72 | -20° | 4.60 | 4.00 | |
|
RAS-16P2AVSG-E/RAS-B16N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.72 | -20° | 4.60 | 4.00 | |
|
MUZ-AY50VGH/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VGH2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.74 | -20° | 5.00 | 4.20 | |
|
AOEH14KGCG/ASEH14KGTG
ASE**K
|
FUJITSU | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTG
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOYH14KGCG/ASYH14KGTG
ASY**K
|
FUJITSU | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
ROH14KGCG/RSH14KGTG
RS**K
|
FUJI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOHH14KGCG/ASHH14KGTH
ASH**K
|
GENERAL | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
AOYH14KGCG/ASYH14KGTG
ASY**K
|
Fujitsu Atlantic | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
U-50PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.61 | -20° | 5.00 | 4.00 | |
|
MUZ-EF42VG/MSZ-EF42VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -15° | 4.20 | 3.80 | |
|
MUZ-EF42VG2/MSZ-EF42VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -15° | 4.20 | 3.80 | |
|
RAC-VJ50WHAE / RAK-VJ50RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.60 | 3.85 | -15° | 5.00 | 4.35 | |
|
RAS-16J2AVSG-E1/RAS-B16N4KVRG-E
HAORI
|
TOSHIBA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
RAS-16J2AVSG-E1/RAS-B16G3KVSG-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
RAS-16J2AVSG-E1/RAS-B16G3KVSGB-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHPF046D1A0TEE
40WHP
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHHW046D1A0TEE
40WHH
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
38WHSH046A1A0TEE/40WHHB046D1A0TEE
40WHH
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.62 | -15° | 4.60 | 4.00 | |
|
AS42KBAHRA-MB/1U42MS3FRA
Coral
|
HAIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.70 | 3.71 | -10° | 4.20 | 3.60 | |
|
AS42KBAHRA-MW/1U42MS3FRA
Coral
|
HAIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.70 | 3.71 | -10° | 4.20 | 3.60 | |
|
MUZ-EF42VE/MSZ-EF42VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 3.70 | -15° | 4.20 | 3.80 | |
|
MOX431-18HFN8-QRD6GW/MSGPCU-18HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MOX431-18HFN8-QRD6GW/MSEZCU-18HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EZ-18RD6-O/EZ-18RD6-I
Solstice
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EZ-18RD6H-O/EZ-18RD6-I
Solstice
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 |